Welcome Customer !

Membership

Wuhan Huatian Electric Power Automation CO., LTD
Free Member ·1YRS
,
Other

Main Products: 电力试验设备

Xwboo>Products

SMG2000E Double Clamps Digital Phase Meter

Model
Nature of the Manufacturer
Other
Product Category
Six、Relay Protection and Secondary Circuit Test Instrument
Place of Origin
City, Province
Overview
Tongs type current transformer input measured current and protection function by conversion mode High contrast Liquid crystal display, words up to 25mm, The screen Angle can be freely converted about 70° Pressure resisting function, edge breaking function
Product Details

Product Introduction

Digital double clamp Phase voltammeter is a high-precision, low-price, hand-held, double-channel input measurement instrument designed for voltage, current and Phase measurement on site.Using this meter, the phase between u-u, i-i and u-i can be easily measured in the field, the phase sequence of sensitive and capacitive circuits and three-phase voltage can be distinguished, the wiring group of transformers can be detected, the secondary circuit and bus differential protection system can be tested, the phase relationship between CT of each differential protection group can be read out, and the wiring of the electricity meter can be checked.The tongs current transformer is used to input the measured current, so there is no need to disconnect the measured line.When measuring the phase between u1-u2, the two input circuits are completely insulated and isolated, so it completely avoids the possible short-circuit of the measured circuit caused by wrong wiring, and thus burns out the measuring instrument.The display screen USES high-contrast Liquid crystal display with words up to 25mm, and The screen Angle can be freely converted to about 70° to obtain better visual effects.

Digital double clamp Phase voltammeter enclosure USES engineering insulation materials, another rubber vibration protection sleeve, safe and reliable.

Product names:Phase meter, double clamp Phase meter, double clamp Phase voltammeter, clamp forms a table, clip-on Phase voltammeter, Digital Phase double clamp Phase meter, Digital double clamp table, low-pressure volt-ampere Phase inspection table, hand-held Digital double clamp Phase voltammeter, double clamp type Digital Phase meter, double clamp Digital Phase meter, double clamp type volt-ampere Phase meter, double clamp volt-ampere Phase table, double clamp Phase meter, Digital display double clamp Phase voltammeter

Product parametersProduct Parameters

Reference to working conditions

Environment temperature (23±5)℃
Environmental humidity (45~75)% RH
Measured signal waveform Sine wave、β=0.02
Measured signal frequency (50±0.2)Hz
The position of the measured current-

carrying conductor at the clamp mouth

any
The amplitude of The measured signal when

measuring The phase

100~220V、0.5~1.5A
External reference frequency electromagnetic

field interference

Should be avoided

Measurement error of AC voltage

Limit of quantity Resolution Basic error limit
20V 0.01V ±(0.3% reading +0.2% range)
200V 0.1V
500V 1V

Measurement error of ac current

Limit of quantity Resolution Basic error limit
200mA 0.1mA ±(0.3% reading +0.2% range)
2A 1mA
10A 10mA

Voltage input circuit impedance when u1-u2 phase is measured:40KΩ

Range Resolution Basic error limit
0~360° 1° ±2°

Rated working condition

Environment temperature (0~40)℃
Environmental humidity (20~80)% RH
Measured signal waveform Sine wave、β=0.05
Measured signal frequency (50±0.5)Hz
The position of the measured current-

carrying conductor at the clamp mouth

any
The amplitude of The measured signal when

measuring The phase

U1-U2 phase: 30V ~ 500V
I1-I2 phase: 10mA ~ 10.00A
U1-I2 phase or I1-U2 phase: 10V ~ 500V, 10mA ~ 10.00A
External reference frequency electromagnetic

field interference

Should be avoided
Limit of rated operating error Under the above rated working conditions, the rated working error limit of each measured shall not exceed twice the corresponding basic error limit

Other technical features

Display digit Three and a half
Sampling rate 3 times per second
The power supply Single 9V laminated battery, The power supply current is less than 5mA
Overall dimensions Case size 192×95×55mm3
Clamp shell size 140×42×20mm3
Jaw size Φ7mm×9mm
Weight Body 280g
Test forceps 2×200g
Storage conditions The temperature -10℃~50℃
Note:

1.The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice.In case of misappropriation or copying, legal liability will be investigated.

2.For more information about huatian products, please enter Product center .Service :qiao@hvtest.cc

Product Characteristics

  • 1、Delicate structure, easy to use: handheld structure
  • 2、In The scope of 10mA ~ 10A current, 3V ~ 500VvoltageThe scope of phase measurement without breaking The circuit and changing The limits
  • 3、The display adopts high-contrast Liquid crystal display with words up to 25mm and The screen Angle can be freely converted to about 70° to obtain better visual effects
  • 4、The switch has a reasonable function and layout. The voltage, current and its phase can be sensed by turning the switch
  • 5、Insulation resistance: new patent Current clamp, Current resolution up to 0.1mA;The resolution rate is 0.1v
  • 6、Low power consumption: the digital double-clamp Phase voltammeter is designed for micro-power consumption and has the function of detecting battery voltage

The product video Product Video

Similar Product Recommend