For standard STM-PW, the maximum heating temperature is 180℃/356℉.
4.3" Touch screen controller with easy to use HMI and clean display.
Adopt SSR solid-state relay controller.
Adopt plate heat exchanger for direct cooling and accurate temperature control, and the low water viscosity makes quick heat exchange.
P.I.D controller with 3.2" LCD with a user-friendly interface. The multi-stage controller can maintain stable mould temperature with a precision of +/- 0.5℃/0.9oF.
In build weekly timer with℃/oF. unit conversion.
In build multiple safety with display and alarm buzzer, such as reverse phase, pump overload, overheat, and low water pressure.
Built-in magnetic pump without seal.
RS485 communication interface achieves centralized monitoring with the host.
Equipped with water level probe and high-pressure plunger pump that could accurately detect the water level, and refill during high-pressure as to avoid empty water system.