Lifting Jack Dynamic Load Testing Machine
Lifting Jack Dynamic Load Testing Machine
Main design criteria of the testing machine- JB2104-2002 standard of hydraulic jack-can meet the factory-leaving test and type test. This testing machine is mainly used for the following products: vertical type upright-blowing lifting jack, vertical type horizontal-blowing lifting jack and horizontal jack.
1. Main Technical Parameter
1)Loading force: 2T, 5 T, 7 T, 10 T, 20 T, 50 T, 100 T
2)Loading length of travel : 0~200mm, 0~500mm, 0~1000mm
3)Hand-operated action times : 0~45 Hand / min
4)Mode of control: Touch screen or computer full automation control
2. Other explanation:
Loading force, loading displacement, hand-operated length of travel,hand-operated action times,loading time and loading times may be set arbitrarily.