Welcome Customer !

Membership

Jiangsu Jiangling Measurement & Control Technology Stock Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 振动显示仪表

Xwboo>Products
Product Categories

Jiangsu Jiangling Measurement & Control Technology Stock Co., Ltd.Free·1YRS

  • E-mail

    jl80283688@163.com

  • Phone

    +86-510-80283688,ext-8888/8021

  • Address

    5 shenjiabang, Yunting street, Jiangyin City

Contact Now

VMS8000 condition monitoring system

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
VMS8000 condition monitoring system
Product Details

System specification

1. Freestyle frame structure

2. Built-in microprocessor, fully intelligent

3. Redundant power supply module design

4. RS485 (Modbus RTU) interface

5. Easy to expand, install and maintain

6. Multiple redundancy and anti-jamming technology

 

application

Various rotating machinery and equipment such as steam turbines, water turbines, generator sets, gear boxes, compressors, water pumps, and fans.

Overview

The system can provide continuous, online monitoring functions, suitable for rotating machinery applications, and fully meet the requirements of enterprise standards for this type of system. The system adopts the form of traditional frame structure, which is flexible and convenient. It has a variety of performances and functions that other systems do not have. The system adopts a modular design including:

VMS8010 chassis frame [required];

VMS8020 requires one or two power supplies (power supply redundancy can meet power supply expansion requirements) [optional redundancy];

VMS8030 requires one communication module [optional];

One or more functional modules of VMS80XX [Required];

The above components will be described in detail below and in the corresponding product manuals of each system component.

VMS8010 system framework

Dimensions

See Schedule 1

Hole Size

See Schedule 1

Installation method 

Disc

VMS8020 power module

Input power  

(1) 90~264VAC/47~63Hz; (2) 120~370VDC

power

≤50W

display

Green OK light is on

description

Provide power for the entire system and modules

VMS8030 communication module

communication method

RS485

Protocol

MODBUS RTU

LED display

(1) "OK" communication module is normal; (2) "TX/RX" communication module communicates with the monitoring module in the chassis frame normally

VMS8090 expansion module (optional)

Types of

Power extension, channel extension

Product number

VMS8110

Shaft vibration module

VMS8130

Swing module

VMS8120

Bearing vibration module

VMS8121

Bearing vibration module

VMS8122

Bearing vibration module

display

LED display

Input signal type

Eddy current sensor

Eddy current sensor

Magnetoelectric speed sensor

Piezoelectric acceleration sensor

Piezoelectric speed sensor

Measurement parameters

Amplitude (pp)

Amplitude (pp), intensity (Trms)

Input channel

Single channel

Precision

±1%FS@25℃

input resistance

>100KΩ

Frequency Range

2-500Hz±3dB

0.5~100Hz

10~300Hz

10~1000Hz

10~1000Hz

Measuring range

Amplitude (1~500μm user-defined), intensity (1~50.0mm/s user-defined)

Sensor power supply

-24Vdc isolation

-24Vdc isolation

No power supply (voltage input)

4.0mA±10%, +24Vdc isolation

4.0mA±10%, +24Vdc isolation

4~20mA current

Large load 750Ω, ±0.1%FS@25℃

Relay

6A/30Vdc, 6A/250Vac, SPDT dry node

Sync signal output

Sensor original signal, output impedance 100Ω, large transmission distance of 300 meters, with two interfaces: BNC socket and backplane terminal

Alarm level

Level 2 alarm

Delay

0~250s, with 1s interval

Alarm value

Custom

Alarm logic

≥

Dangerous bypass

Start, prohibit

Product number

VMS8210 Speed ​​Module

VMS8220 anti-speed module

VMS8230 Key Phase Module

display

LED display

Input signal type

Eddy current sensor, speed sensor

Eddy current sensor, speed sensor

Eddy current sensor

Measurement parameters

Revolution/min (rpm)

Input channel

Single channel

Precision

±1%FS@25℃

input resistance

>100KΩ

Measuring range

1~9999rpm user defined

Sensor power supply

-24Vdc isolation, +12Vdc isolation, no power supply

-24Vdc isolation, +12Vdc isolation

-24Vdc isolation

4~20mA current

Large load 750Ω, ±0.1%FS@25℃

Relay

6A/30Vdc, 6A/250Vac, SPDT dry node

Sync signal output

TTL level, 0~12Vdc, output impedance 500Ω, large transmission distance of 300 meters, with BNC socket and backplane terminal two interfaces

Alarm level

Level 2 alarm

Level 1 alarm (forward and reverse alarm)

no

Delay

0~250s, with 1s interval

0~250s, with 1s interval

 

Alarm value

Custom

Alarm logic

≥

Dangerous bypass

Start, prohibit

Product number

VMS8310 axial displacement module

VMS8320 Differential Expansion Module

display

LED display

Input signal type

φ8mm eddy current sensor; φ11mm eddy current sensor

φ11mm eddy current sensor; φ25mm eddy current sensor

Measurement parameters

Axial displacement

Input channel

Single channel

Precision

≤1%FS@25℃

input resistance

>100KΩ

Measuring range

User-defined according to the selected sensor

Sensor power supply

-24Vdc isolation

4~20mA current

Large load 750Ω, ±0.1%FS@25℃

Relay

6A/30Vdc, 6A/250Vac, SPDT dry node

Buffered signal output

Output impedance 550Ω, with two interfaces: BNC socket and backplane terminal

Alarm level

Level 2 alarm

Delay

0~250s, with 1s interval

Alarm value

Custom

Alarm logic

≥

Dangerous bypass

Start, prohibit

surroundings

Operating temperature

-30℃~+65℃

stored temperature

-40℃~+85℃

humidity

≤90%, non-condensing

Order information

Schedule 1

 

Framing epitope

Number of monitoring modules

Dimensions (mm)

Length × height × depth

Hole size (mm)

l×h

5 people

2

258×161.5×200

227×140

6 digits

3

298×161.5×200

267×140

7 bits

4

338×161.5×200

307×140

8-bit

5

378×161.5×200

347×140

9 bits

6

418×161.5×200

387×140

10 people

7

458×161.5×200

427×140

11 digits

8

498×161.5×200

467×140

12 bits

9

538×161.5×200

507×140

13 people

10

578×161.5×200

547×140

14 bits

11

618×161.5×200

587×140

15 bits

12

658×161.5×200

627×140

Remarks:

Frame epitope = 3 fixed epitopes on the left + the number of monitoring modules.

(1) VMS8000 status monitoring system, where the left card slot is the power module; the left 2 card slot is the redundant power module, the redundant power module is optional, if the redundant power is not configured, the card slot is reserved Power supply expansion channel; the left 3-bit card slot is a communication module, and the communication module is also optional. If no communication module is configured, the card slot is a reserved communication expansion channel. The card slot starting with 4 is the function module card slot.

(2) VMS8000 state monitoring system, the number of chassis = 3 + the number of monitoring modules.

System module

 

Order number

Function module name

description

VMS8010

system framework

required

VMS8020

Power module

Redundant configuration

VMS8030

Communication module

Optional

VMS8090

Expansion module

Optional

VMS8110

Shaft vibration module

Equipped with φ8mm eddy current sensor

VMS8120

Bearing vibration module

With magnetoelectric speed sensor

VMS8121

Bearing vibration module

Equipped with piezoelectric acceleration sensor

VMS8122

Bearing vibration module

Equipped with piezoelectric speed sensor

VMS8130

Swing module

Equipped with φ8mm eddy current sensor

VMS8210

Speed ​​module

Distribution eddy current sensor or speed sensor

VMS8220

Anti-speed module

Distribution eddy current sensor or speed sensor

VMS8230

Key Phase Module

Distribution eddy current sensor

VMS8310

Axial displacement module

Equipped with φ8mm eddy current sensor or φ11mm eddy current sensor

VMS8320

Differential expansion module

Equipped with φ18mm eddy current sensor or φ25mm eddy current sensor

 

Scan the QR code to read on your phone