Overview
The transmitter adopts a two-wire system and provides a 4-20mA current signal, which is proportional to the vibration speed of the bearing bush or bearing seat of the rotating machinery. It automatically collects vibration signals on the machine and uses the converted analog signals in PLC, DCS and DEH systems, etc.
Application areas are
used for rotating and reciprocating machines, such as fans, centrifuges, pumps, motors, reducers, industrial fans, heat exchangers/cooling towers, air-cooling island fans, generators, piston compressors, centrifugal compressors, Stone crushers, compressors, pumps, coal mills, etc.
Technical Parameters
Signal 1. Measurement parameters: Speed 2. Number of channels: Single channel 3. Accuracy: ±1%FS@25℃ 4. Sensitivity: 0.0 to 20.0mm/s (default) ±5%, Trms (true effective value) [4mA Equal to 0.0mm/s and 20mA equals to 20.0mm/s (default)] 5. Frequency response range: 10Hz-1KHz 6. Measuring range: 0-20.0mm/s (default), 0-50.0mm/s can be customized Output 1, 4~20mA: large load 750Ω Environment 1. Working temperature: -40℃~+80℃ 2. Storage temperature: -45℃~+85℃ 3. Relative humidity: ≤99% without condensation and no immersion | Physical 1. Diameter: 29.8mm 2. Height: 60.5mm 3. Material: Stainless steel 4. Output interface: MIL-C-5015, 2-pin (A, B end) 5. Mounting thread: M8 internal threaded hole 6. Protection: IP67 7. Weight: 100g 8. Connector wiring convention: Pin A: 4-20mA forward loop, Pin B: 4-20mA negative loop Power supply 1. Power supply voltage: 18~30 Vdc (typically 24Vdc) |
Order information
Main part 1: Transmitter
Order number | Measuring range A | Other B | description |
VMS1120-Ax-Bxx | 10.0≤A≤50.0mm/s, the default measurement range: 0-20.0mm/s. For example: A20.0=Measuring range: 0-20.0mm/s. | 00: No requirement | The transmitter output connector is a 2-pin MIL socket |
Note: The required options for the vibration transmitter include: [Main part 1: Transmitter, accessory 1: Connecting cable, accessory 2: Installation conversion base and accessory 3: Mounting bolts].
Annex 1: Connecting cable
| Order number | Cable length A | Other B | description |
VMS600901-Ax-Bxx | Range: 1m≤A≤300m, in increments of 0.5m, default 3m. For example: A2.5=Cable length is 2.5 meters. | 00: No requirement | 2-pin MIL-C-5015 plug, with xm 2-core shielded twisted wire cable, diameter 4mm, <120℃. |
VMS600801-Ax-Bxx | 2-pin MIL-C-5015 plug, with xm 2-core shielded twisted armored cable, diameter 8mm, <150℃. |
VMS600701-Ax-Bxx | 2-pin MIL-C-5015 plug (right angle), with xm 2-core shielded twisted wire armored cable, diameter 8mm, <150℃. |
VMS600601-Ax-Bxx | 2-pin MIL-C-5015 sealed plug with xm 2-core shielded twisted wire cable, diameter 4mm, <120℃. |
Attachment 2: Installing the conversion base (standard configuration)
| Order number | description |
VMS600902 | Including 1/4-28UNF to M8×1 mounting bolts |
Attachment 3: Mounting bolts
| Order number | description |
VMS602103 | M6×1 |
VMS602203 | M8×1 |
VMS602303 | M10×1 |
VMS602403 | M10×1.5 |
VMS602503 | 1/4-28UNF |
Note: Installation bolt length: 9mm