Application Field
1. For low pressure water supply;
2. Home HVAC circulation system;
3.Industrial water circulation system, cooling water circulation system;
Working conditions
1. Power supply: 220V, 50Hz single-phase alternating current;
2. Maximum system pressure: 0.5MPa;
3. Insulation class: F;
4. Protection level: IP44;
5. Ambient temperature during work: 0℃~40℃;
6. The temperature of the conveying liquid: 0℃~90℃;
7. Delivery liquid: clean water.
Parameter Technical Data:
| Maximum flow(m3/h) | 80 | Rated flow(m3/h) | 38 |
| Maximum head(m) | 15 | Rated head(m) | 10 |
| Inlet pipe diameter | 25mm | Outlet pipe diameter | 25mm |
| Input power(kW) | 320W | Output power(kW) | 200W |
Performance Curve:
H-----Head
P1----Input Power
EM----Efficiency
Q-----Flow
Installation Dimension Drawing:

Product production process testing items
1. Motor detection
1.1 Motor turn-to-turn impact detection;
1.2 Motor insulation resistance detection;
1.3 Motor ground withstand voltage detection;
1.4 Motor winding DC resistance detection;
1.5 Motor steering test.
2. Assembly workshop
2.1 Grounding resistance detection of the whole pump;
2.2 Insulation resistance detection of the whole pump;
2.3 Pump withstand voltage leakage current detection;
2.4 Pump leakage current detection;
2.5 Low-voltage start-up detection of the whole pump;
2.6 No-load power detection of the whole pump;
2.7 No-load current detection of the whole pump.
Type test of the pump in the laboratory
1. Hydraulic performance inspection of the whole pump;
2. Noise and vibration detection of the whole pump;
3. Temperature rise test of the whole pump;
4. Blockage test of the whole pump;
5. Low voltage start;
6. IP rating test.