Scope of use
Air source heat pump combined supply system
Product certification
The product meets the requirements of TUV、CE、EMC、RoHS、REACH、EEI≤0.23-part3 certification
Basic parameters
| Rated voltage :220-240V AC | Rated current :1.9A | Frequency :50/60Hz |
| Maximum flow :7m³/h | Maximum head :15m | Maximum power :300 W |
| Rated flow :5 m 3/h | Rated head :11 m | Design pressure :1.0MPa |
| Noise :<48dB(A) | EEI≤0.23-part3 | Protection class:IP44 |
| Standby power :≤2W | Insulation class :H | Temperature class :TF95 |
| Steering: clockwise when Viewed from the pump inlet | Weight :About 5kg(complete machine) | Surge current :<10A |
Media requirements
| Medium: water or water + glycol (≤ 50%)mixture | Medium temperature : 2℃∼95℃ |
| PH value of medium :6.5-8.5 | Medium hardness :25°dH |
| Content of solid impurities in medium: diameter and length direction of solid impurities ≤ 0.1mm, and volume ratio ≤ 0.1% | |
Service environment requirements
The working environment temperature of the pump should be synchronized with the
medium temperature of 2~95℃, as shown in the figure on the right (the maximum ethylene
glycol concentration is 50%, that is, the mediumThe minimum temperature is -30℃)
Start and stop of pump
Starting time: the starting time of the water pump is less than 8S, the time
from power on to reaching the maximum speed
In PWM mode, when starting from the stop state of the water pump (without power
supply), 90% of the maximum speed must be reached in at least 8 seconds
In PWM mode, start from standby mode and reach 90% of the maximum speed in
at least 8 seconds
Shutdown time: the shutdown time of the water pump is less than 1 s, that is,
the time from power failure to shutdown of the water pump
Performance curve

This performance curve is suitable for normal temperature water, such as pump for
non-water medium, the hydraulic performance of the pump will be reduced , therefore ,
in the selection of pump, must consider the characteristics of the liquid medium
Installation dimension drawing

Product connection
12.1 Power connection
Voltage: 220-240V AC(±10% )
Frequency:50/60Hz
12.2 Signal connection(PWM)
PWM input signal voltage:4-24V
minimum input current:4mA
PWM input signal frequency: 100-2000Hz
PWM output signal: collector open-drain output, must be connected to a pull-up resistor,
the voltage is selected according to the signal acquisition range of
the host computer