Product Categary: Residential Membrane Element Main Feature: It has the selective desalination mechanism for removal of high polyvalent ions and partial maintaining of monovalent ions with health benefits. Moreover, home drinking NF1 membrane elements can achieve as the high rejection, ultra-low operating pressure for des......
Usage
It is applicable to the desalination of raw water with salt concentration less than 500ppm. It can be widely applied to various small size household water purification, mineral water machine and energy machine etc..
Specifications & Parameters
| Model | Active Membrane Area ft2(m2) | Permeate Flow GPD(m3/d) | Stable Rejection Rate (%) | Solution Type |
| NF-2012 | 6.3(0.59) | 150(0.57) | 30-50 | NaCl |
| >96 | MgSO4 |
Standard Test Condition
| Concentration of Solution | Temperature(℃) | pH Value | Operating Pressure psi(MPa) | Recovery Rate(%) |
| 500mg/L NaCl | 25 | 7.5-8 | 70(0.48) | 15 |
| 2000mg/L MgSO4 | 25 | 7.5-8 | 70(0.48) | 15 |
Notes:The permeate flow of single membrane element may vary with in ±15%.
Operating Limits and Conditionsof Membrane Element:
| Max.Working Pressure | 300 psi(2.07MPa) |
| Max. FeedWater Temperature | 45 ℃ |
| Max. FeedWaterSDI15 | 5.0 |
| Free Chlorine Concentration of FeedWater | 0.1mg/L |
| pH Range of FeedWaterDuring Continuous Operation | 3-10 |
| pH Range of FeedWaterDuring Chemical Cleaning | 2-12 |
| Max. Pressure Drop of Single Membrane Element | 10psi(0.07Mpa) |