Welcome Customer !

Membership

DePro Pump (Zhejiang) Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 泵

Xwboo>Products

DePro Pump (Zhejiang) Co., Ltd.Free·1YRS

  • E-mail

  • Phone

    0572-2909803,400-185-8229

  • Address

    No. 2688, Nianfeng West Road, Nanxun Economic Development Zone, Huzhou City, Zhejiang Province

Contact Now

GM series mechanical diaphragm metering pump

Model
Nature of the Manufacturer
Other
Product Category
Metering pump
Place of Origin
City, Province
Overview
GM series mechanical diaphragm metering pump
Product Details

Main performance parameters of GM series mechanical diaphragm metering pump

● maximum flow of single head: 500L / h

● maximum discharge pressure: 12bar

● regulation ratio 10:1, steady-state accuracy 2%

● suction lifting height up to 3m water column

● the maximum inlet pressure is 2 bar

● the maximum allowable material temperature is 40C

Main features of GM series mechanical diaphragm metering pump

Drive end

● variable eccentric mechanism adjustment to ensure smooth flow pulsation

● enhanced structural design, suitable for harsh operating environment

● wear resistant ball bearing makes the work more stable

● oil bath lubrication, long service life of driving parts

● the flow can be adjusted under shutdown or operation, and the adjustment mode can be manual, electric or frequency conversion

Hydraulic end

● the diaphragm is mechanically driven, and there is no diaphragm protection plate on the material side to facilitate the passage of materials

● PVC, PVDF. 316SS. High viscosity, slurry and other pump head materials, suitable for all kinds of materials

● self cleaning check valve structure

Main application

● municipal, industrial water and wastewater, swimming pool and other water treatment processes

control mode 

◆ the electric stroke controller receives the external control signal and adjusts the stroke length

● power supply: 220V-50HZ single phase

● input signal: 4-20mA analog signal

● output signal: 4-20mA / 1-5V analog signal for recording, display and control system

◆ variable frequency controller, which receives external control signals and adjusts stroke speed

● power supply: 220v-50hz-single phase / 380-50hz-three phase

● input signal: 4-20mA analog signal

◆ the motor controller controls the three-phase motor in the "on / off" mode to adjust the output flow

● power supply: 200 - 240V / 50 / 60Hz / single phase

● control mode: it can accept 4-20mA analog signal, external pulse signal or manual adjustment

GM pump

Pump head material

GM0002 -GM0050

GM0090-GM0500

Interface codeABCInterface codeABC
PVCP108116250
Q127159
322
PVDFP108N131
316N102N131


Material of main components of hydraulic end

GM0002-GM0500

Material of 

hydraulic end

Valve body

Valve seatValve ball

The

 diaphragm

Seal ringConnect
PVCPVCPVDFZirconiaPTFEFPM/EPDM*/Fluorinated*PVC
PVDFPVDFPVDFZirconiaPTFEFPM/EPDM*/Fluorinated*PVDF
316SS316SS316SS316SSPTFEFPM/EPDM*/Fluorinated*316SS


Model definition of GM series mechanical diaphragm metering pump

Series

Code

Describe

GM

GM series mechanical diaphragm metering pump


Flow

Code

Maximum flow(L/h)

Maximum 

pressure

(bar)

Number of strokes(min¯¹)electric machinery(kw)
GM0002
2.2512
36

0.25●

0.37■


GM00054.536
GM0010936
GM00252572
GM00505010144
GM0090857
72
GM012011572
GM0170170144
GM0240235144
GM03303155
144
GM04004001440.37
GM0500500180

●This power is used for three-phase constant speed, explosion-proof motor    ■This power is used for single-phase, explosion-proof, variable-frequency motor 

Hydraulic end

Code

Describe

CodeDescribe
PPVC Hydraulic endVHigh viscosity application: PVC hydraulic end
S316 Hydraulic endKSlurry application:GM0025-0500
TPVDF Hydraulic endM

Mixture application, GM: PVDF hydraulic end

FApplication of sodium hypochlorite in PVC hydraulic end◆ZSpecial material hydraulic end, please consult factory, and explain when ordering

◆EPDM O-ring

Interface:

CodeDescribeGM0002-0050GM0090-0500
PVCPVDF316
PVCPVDF316
PNPT threaded connection1/2"F1/2"F1/2"F1/2"F1/2"F1/2"F
QHard tube intubation interface of inner tube orificeDN15————DN15————
RHose connection6×12▲6.35×9.52★————————
H

GM hose for high viscosity applications

12×18————20×28————
XSpecial interface
Please consult factory and explain when ordering

Note: the parameters in red are standard configuration. If there are no special options for high viscosity pump head V, slurry pump head K and mixture pump head m, the interface shall be selected according to the material of hydraulic end.

The length of PVC hose is 6m / piece; One hose is configured by default. The factory is not equipped with injection valve, bottom valve, counterweight and Teflon hose. Please order extra and inquire from the factory.

Electric machinery:

Code

Describe

1

0.25kW, 1EC71,three-phase 380V,50Hz, 1440rpm, IP55/F

2
1/3P,NEMA56C,three-phase 380V,50Hz, 1440rpm, NEMA3/TEFC
3

0.37kW, IEC71,three phase explosion proof 380V,50Hz,1440rpm, IP55/F, dIIBT4

40.37kW, IEC71,three-phase 380V,50Hz, 1440rpm,IP55/F
50.25kW, IEC71,three-phase 220V, 50Hz,1440rpm, IP55/F
6

0.25kW, 1EC71,three phase frequency conversion 380V, 50Hz, 1440rpm, IP55/F, IC416

7

0.37kW, IEC71,three phase frequency conversion 380V, 50Hz, 1440rpm, IP55/F, IC416

8————————
9(5)The pump is not equipped with motor, and iec71 interface is reserved
9(6)0.37kW, 1EC71,single-phase 220V,50Hz, 1440rpm, IP55/F
9(8)————————
9For other motors, please consult factory


Adjust:

CodeDescribeRemarks
M
Manual stroke adjustment

Standard

 configuration

NElectric stroke adjustment,4- 20mA, 1PH- 50Hz-220V——
E——————————
FFrequency conversion control——