Product model
BT300-1F Dispensing type Peristaltic Pump
[Product introduction]
Flow range: 0.07-1300mL/min
The best filling volume: 1-100mL
Various pump head for optional, YZ series、BZ series
Working mode: Flow mode, Dispensing type mode
Flow rate rectify, Dispensing type volume rectify function
Flow accuracy within ±0.4%
[Application]
Lab, filling
Reagent packing, culture medium filling
[Technical parameter]
Model | BT300-1F Dispensing type Peristaltic Pump |
CPU | ARM Cortex-0 Core,STM32 Chip |
Motor drive chip | SANYO THB6128 drive chip |
Speed adjustable range | 1-300RPM |
Speed resolution | 1RPM |
Distribute function | liquid Quantitative filling accurately |
Dispensing type range | 0.1mL-999L |
Filling times | 1-9999 times |
Display function | 128×32 Dot matrix LCD display, flow rate and speed display in the same screen |
Direction control | Clock-wise/counter clock-wise direction reversible |
Operation mode | Rotating code switch combine with Membrane keypad adjust the speed, also support external signal adjust speed |
Full speed function | Full speed button to realize fast filling and drain |
Power-down memory function | After power on, running as before |
Back suck function | Running under Dispensing type mode, pump reverse a certain angle after stopping, to prevent liquid drip |
Calibration function | Flow rate rectify function, convenient and fast ; accuracy ±0.5% |
Dispensing type Calibration function | Input filling volume , it rectify the distributed liquid automatically; accuracy ±0.5% |
External control function | Different model external control module for Start/Stop, direction, flow rate; 0-5V、0-10V、4-20mA、0-10KHz 4 module for option |
Communication function | Optional communication module, RS485 communication control (via Modbus protocol) |
Foot switch control | Optional |
Bracket | Optional (for installing the nozzle) |
Nozzle | Various specification nozzle for option, nozzle inner diameter 2.2mm、2.5mm、3mm、4mm、6mm |
Power consumption | 50W |
Power supply | Wide AC90-260V,50Hz/60Hz |
Operation condition | Temperature 0 to 40 °C, Relative humidity < 80% |
Driver weight | 4.8KG |
IP rate | IP31 |
[Selection guide]
Filling volume | Filling time (Sec) | Accuracy | Recommend driver | Recommend pump head | Recommend tube |
10 mL | ≥0.80 | ±1.0% | BT300-1F | YZ15 | 25# |
20 mL | ≥1.57 | ±0.8% | 25# |
30 mL | ≥2.39 | ±0.5% | 25# |
50 mL | ≥2.70 | ±0.5% | BT600-1F | YZ15 | 25# |
100mL | ≥3.25 | ±0.4% | 17# |
Driver | Pump head | Pump head roller | Pump head QTY | Tube | Speed range(RPM) | Flow range (mL/min) |
BT300-1F | YZ15 | 3 | 1,2 | 13# | 1-300 | 0.08-23 |
14# | 0.27-88.6 |
19# | 0.52-165.3 |
16# | 0.86-270.9 |
25# | 1.8-558.3 |
17# | 3.2-968 |
18# | 4.1-1343 |
YZ25 | 3 | 1,2 | 15# | 1-300 | 1.7-530 |
24# | 2.9-871 |
BZ15-14 | 3 | 1,2 | 14# | 1-300 | 0.23-88.8 |
BZ15-16 | 16# | 0.79-270.9 |
BZ25A | 24# | 2.5-871 |
Remarks:
Above data are tested actually by silicone tube, various import tube for option
Import tube to prolong tube lifetime and accuracy
[Dimension] 