Summary: XBC series electric or diesel engine fire fighting pump is required to meet the standard GB6245-2006 and international fire pump standard NFPA20, Which designed by YONJOU PUMP. XBC fire pump is a fixed fire fighting device. Mainly be applied for water and foam extinguishing system in...
Product Details
Summary:
XBC series electric or diesel engine fire fighting pump is required to meet the standard GB6245-2006 and international fire pump standard NFPA20, Which designed by YONJOU PUMP. XBC fire pump is a fixed fire fighting device.
Mainly be applied for water and foam extinguishing system in petrochemical industry, natural gas, power station, cotton and linen textile industrial, warehouse, airport, wharf, high-rise buildings, and etc. And also available for ship, tanker, fire fighting naval vessels and etc. XBC fire pump can be equipped with Chinese brand good quality engine or import engine either.
YONJOU fire fighting pump can provide quick start, reliable water supply, suitable power supply, stable running, standardization, individualization, optimization, and wide range in pressure rate and flow rate. YONJOU brand XBC NFPA20 standard fire frighting pump is a dependable fire device.
Ensure the pump can continue on duty, fully pay emergency functions and long-life time, the proper maintenance is required.
To insure the operator fully understand the structure of the pump, operation and maintenance, right installation, YONJOU redact this manual for reference.
Specification data:
Model
Diameter
Capacity
Pressure
Engine Power
Speed Range
End Suction Fire fighting pump
2-8 inch
160-1760 GPM
0.5-12.5 bar
0.22-110kW
1500RPM 1800RPM 2200RPM
2500RPM
2800RPM 3000RPM
Multistage Fire fighting pump
1.5-12 inch
16.5~3740 GPM
1.9~81.6 bar
3-1600 kW
Split Case Fire fighting pump
3-18 inch
64~11000 GPM
0.61~20 bar
2.2-1800 kW
Submerged Fire fighting pump
6-40 inch
220-36960 GPM
1.5-15 bar
5.5-2000 kW
Service condition:
Atmosphere
>90kpa
In abnormal condition, engine rated power may lower then normal.
Ensure working safe, a bigger engine required at work is better.
Note: Measurement of engine rated power is tested in following condition.
Atmosphere
=100kPa
Ambienttemperature
5-40℃
Ambienttemperature
=25℃
Relative airhumidity
=30%
Relative airhumidity
≤80%
Every 100m altitude higher the rated power of engine drop 3%.
Applicable diesel engine
Engine rated power 10% more then pump absorbed power
Every 5.6'C ambient temperature higher the rated power of engine drop 1%.
Engine real power output=(CA+CT-1)x Rated power
Standard configuration:
Water pump: Single stage end-suction centrifugal fire pump, multistage fire pump, single stage double-suction fire pump, submerged fire pump, rotor fire pump, according with GB6245-2006《 Fire pump testing demand and testing method》 and NFPA20(National fire protection association).
Engine: Water cooling engine
1. Single cylinder engine: battery; air, fuel, lubricant filter system; exhaust system with muffler assembly; engine water cooling system; fuel tank; auto start control box(no protection system, manual stop).
2. Multicylinder engine: battery; air、 fuel、 lubricant filter system; exhaust system with muffler assembly; engine water cooling system; fueltank; engine monitor; PLC editor, auto start control box(normal standard protection system or NFPA20 type).
Functional characteristics:
Wide range of pump
Fire pump can equip with end-suction pump,multistage pump,double-suction pump, rotor pump,wide range of flow and head.
Auto operation
Once the fire pump received a fire signal,or power failure、lose phase of electric motor pump, or received a remote start signal,the pump set will auto start.
Pump crank for 10 seconds,and if start failure it will restart again. Repeat the starting procedure up to 3 times.
Indicator and alarm
Multiple start failure alarm,engine low lubrication alarm,engine high water temperature alarm,engine over speed alarm,low battery voltage alarm. battery charge failure alarm,low fuel level alarm.
Multiple start mode
Manual,a variety of automatic start.
Auto shut down
Pump auto shut down by the fire signal disappeared.
Remote connect terminals
terminals as remote start, stop, pump set running, pump set comprehensive failure,etc.
Direct connection
A coupling between engine and pump is required to directly connect, by this connection fewer failure and smaller vibration will have.
Auto battery charging
When Auto mode on,during the standby time,a charger can supply a constant current, voltage to insure the battery have enough power. Once the battery fully charged, the charger will cut off the current automatically for in case the damage.
Adjustable rated speed
Through adjusting engine speed,the pump flow and head can be adjusted to the required point.
Double power supply
The starting current will be absorbed from either power supply alternately. If one set of power failure will change to anther one automatically.(Optional)
Maintenance-free battery
No need to frequently refill the electrolyte.(Optional)
Pre-heat
Make sure the engine can start normally in cold weather.(Optional)
Timing start
Available to set timing start,to test pump could run regularly.(Optional)
Why choose us:
A. The well respected manufacturer of fire fighting since 1989.
B. We have a Young and dynamic sales team.
C. Experienced professional technicians. Taking pride in our products.
D. Quality assurance! 99% tested before shipping to customers.
Customized according to customers’ demands.
Hot Tags: electric fire fighting pump, China, manufacturers, suppliers, factory, price, for sale, Acid Transfer Pump, 6 inch dewatering pump, Large Capacity Water Pumps, Air Diaphragm Pump, portable gear pump, boiler pump