Welcome Customer !

Membership

RICITE (ZHE JIANG) TECHNOLOGY CO.,LTD.
Free Member ·1YRS
,
Other

Main Products: 泵

Xwboo>Products
Product Categories

RICITE (ZHE JIANG) TECHNOLOGY CO.,LTD.Free·1YRS

  • E-mail

    sales@ricite.com

  • Phone

    400-169-7088\86-572-2161515

  • Address

    No.3789 ShuShan Road,WuXing District,HuZhou City,Zhejiang Province,China

Contact Now

RMD Stainless steel magnetic drive centrifugal pump

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
the main feature of RMD / RMI stainless steel magnetic drive centrifugal pump (referred to as magnetic pump) is that when the outer magnetic steel of magnetic coupling rotates, the magnetic force line passes through the gap and is···
Product Details

Product overview

RMD / RMI stainless steel magnetic drive centrifugal pump (referred to as magnetic pump). The main feature is that when the outer magnetic steel of the magnetic coupling rotates, the magnetic force line passes through the gap and isolation sleeve and acts on the inner magnetic steel to make the pump shaft rotate synchronously with the motor and transmit torque without contact. At the power input end of the pump shaft, because the liquid is sealed in the static isolation sleeve without dynamic seal, the inevitable phenomena of running, emitting, dripping and leakage in the petrochemical industry are eliminated, and there is no leakage at all. This type of pump is suitable for conveying toxic, harmful, flammable, explosive and valuable liquid media. It is an ideal pump for creating leak free, pollution-free civilized workshops and civilized factories.

Application area

RMD / RMI series magnetic pumps are applicable to petroleum, chemical, pharmaceutical, electroplating, environmental protection,food, film and television printing, water treatment, national defense and other industries. It is an ideal equipment for transportingflammable, explosive, volatile, toxic, valuable and various corrosive liquids.

双图.jpg


Use environment

The flow passage parts of RMD / RMI series magnetic pumps are mainly made of austenitic stainless steel, and can also be equipped with non-metallic lining or hotsolid plastic. These pumps are collectively referred to as metal magnetic pumps. They are suitable for conveying liquids without ferromagnetic particles and fiberswith a maximum pressure of 1.6Mpa, a temperature of no more than 120P and a viscosity of no more than 30x 10-6nws. When the pressure of the conveying mediumsystem is greater than 1.6Mpa and the temperature exceeds 120P, and supporting thermal insulation measures are required, the unit can carry out special design and manufacturing.


Performance range (rated point)

Diameter 32 ~ 300mm

Flow 3.2~ 1000m3 / h

Lift 8 ~ 150m

Temperature - 20p ~ + 120P (customized as required + 120x) ~ + 350x)

Pressure 0 ~ 1.6Mpa (customized 1.6 ~ 30MPa as required)

Steering motor clockwise

Power 1.1 ~ 315KW


Structure diagram

RMD / RMI magnetic pump is mainly composed of pump body, impeller, pump shaft, bearing, bearing body, isolation sleeve, thrust ring, coupling frame, magnetic driver and other parts. See the structural drawing for details:

1.jpg

Structural features

► single stage, single suction horizontal centrifugal pump.

► CFD computational fluid dynamics design hydraulic components, with wide flow channel, high efficiency, good cavitation performance and small radial force.

> the flow passage parts adopt precision casting mold modeling, with accurate size, fresh and clean flow channel and high efficiency.

> permanent magnetic materials with high performance and high temperature resistance shall be selected to ensure sufficient magnetic torque.

> the isolation sleeve design of low vortex flow makes the pump more efficient.

> modular design of parts and components with good interchangeability.

> the sliding bearing and pump shaft are made of pressureless sintered silicon carbide with high hardness, high wear resistance and high corrosion. The unique double bearing centering and positioning structure design is equipped with hydrodynamic lubrication structure to ensure the reliability of pump operation and the service life of the bearing.

> special lubrication and cooling design: the internal circulation liquid flow is used to take away the heat generated by eddy current on the isolation sleeve and lubricate the sliding bearing, so as to automatically balance the axial force of the pump and ensure the safe operation of the pump. The reasonable structural design makes all internal circulation systems have sufficient pressure and flow to ensure the stable operation of the pump.

► the isolation sleeve has the ability of completely draining the medium (when the pump is stopped for repair) and automatic emptying (when filling before startup). It is generally made of high-quality stainless steel and advanced technology.

► cooling or heating, thermal insulation, convenient disassembly and other devices can be added when required by working conditions



Model description:

2.jpg

Protector

► the load controller is used to detect the power consumption of the motor, and the power consumption of the motor can be set in a safe interval in advance. When the pump is subject to cavitation, cut-off and magnetic drive

In case of low load caused by dynamic slip or overload caused by mechanical contact of rotating workpieces, the power supply can be automatically cut off to stop the pump, so as to protect the pump from further damage.

► the temperature sensor indirectly detects the temperature of the internal circulation system by detecting the temperature of the isolation sleeve. If the temperature exceeds the set range, it can generate an alarm signal or

The electrical signal is used to control and cut off the power supply, so as to protect the equipment.

► double isolation sleeve design. The leakage of inner and outer isolation sleeves can be monitored by leakage instrument. Ensure that the magnetic pump can operate normally in more severe situations.


◎Installation and commissioning

The quality of pump installation has an important impact on the operation and service life of the pump, so the installation and correction must be carried out carefully!

►Installation and calibration

a. The magnetic pump shall be installed horizontally rather than vertically. For special occasions requiring vertical installation, the motor must be upward.

b. Remove grease and dirt from the base and place the base on the foundation.

c. Check the levelness of the base with a level gauge, and it is allowed to level with a wedge iron.

d、 Pour the base and anchor bolt holes with cement.

e、 After the cement is dry, check whether the base and anchor bolt holes are loose, tighten the anchor bolts when appropriate, and recheck the levelness.

f. Clean the support plane of the base, the plane of the water pump foot and motor foot, and install the water pump and motor on the base.

►Installation instructions

a. The installation height of the pump, the length, diameter and flow rate of the pipeline shall comply with the calculation, and strive to reduce unnecessary losses.

b. Larger pipe diameter shall be adopted for long-distance transportation; The pipeline of the pump shall have its own support, and the weight of the pipeline is not allowed to be added to    the pump to avoid crushing the pump.

c. The discharge pipeline shall be equipped with a check valve and shall be installed in front of the gate valve.

◎ use and operation

► start

a. The pump shall be checked before use, and the fan blade of the motor shall be flexible without jamming and abnormal sound; The rotation direction of the motor shall be consistent with that of the pump.

b. Close the gate valve on the outlet pipeline.

c. Fill the pump with liquid, or use a vacuum pump to drain the gas in the pump.

d、 Turn on the power supply. When the pump reaches the normal speed, gradually open the gate valve on the discharge pipe and adjust it to the required working condition (when the gate valve on the discharge pipe is closed, the continuous working time of the pump shall not exceed 2 minutes).

► operation

During start-up and operation, pay attention to observe whether the readings of each instrument, vibration and noise of the pump are normal. If any abnormality is found, it shall be handled in time.

► stop

a、 Gradually close the gate valve on the discharge pipeline and cut off the power supply.

b、 If the ambient temperature is lower than 0 ° C, discharge the liquid in the pump to avoid freezing crack.

► maintenance

Regular maintenance. Under normal circumstances, after 8000 hours of operation, a disassembly inspection shall be carried out, and the vulnerable parts that are not suitable for reuse shall be replaced.

◎ precautions

1、 Because the cooling and lubrication of the magnetic pump bearing depends on the transmitted medium, it is absolutely prohibited to run by air.

2、 If there are solid particles in the conveyed medium, a filter screen shall be added at the pump inlet (if there are iron particles, a magnetic filter shall be added).

3、 The conveying liquid is the medium of precipitation and crystallization. It shall be cleaned in time after use to drain the accumulated liquid in the pump.

4、 This series of pump magnetic coupling adopts high-performance permanent magnet materials. Please keep the following devices away from this product, such as cardiac pacemaker, credit card and other magnetic cards, phone, watch, etc.

5、 The voltage shall be stable and not easy to be too high or too low. The motor power shall be more than 18.5kw. The pump shall be equipped with frequency converter or self coupling decompression.