Welcome Customer !

Membership

Bucher Hydraulics (Wuxi)Co.,Ltd.
Free Member ·1YRS
,
Other

Main Products: 泵

Xwboo>Products
Product Categories

Bucher Hydraulics (Wuxi)Co.,Ltd.Free·1YRS

  • E-mail

    info.wuxi@bucherhydraulics.com

  • Phone

    +86-510-88551803

  • Address

    No 225, Xitai Road, Meicun, New District, Wuxi,    Jiangsu, P.R.China

Contact Now

Auto Hoist Power Units 1

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
Auto Hoist Power Units 1
Product Details

Auto Hoist Power Units 1

General Description



As one part of our YBZ series power unit family, this power unit is widely used in two-post auto hoists. Push the start button on the motor to lift the machine. The lowering movement is activated by the manual release valve, with the lowering speed controlled by the throttle valve in the return line. The power unit also applies to different kinds of hydraulic fork lift and scissors lift.

Outline Dimension


Model Specifications

Model

Motor Volt

Motor power

Displacement

System pressure

Rated Speed

Tank Capacity

总长(mm)

L1

L

YBZ - E2D3H1/1

220VAC

2.2KW

2mL/r

16MPa

2830rpm

10L

440

717

YBZ - E3B3H1/1

3mL/r

6L

300

577

YBZ - E2C3H1/1

2mL/r

8L

370

647

YBZ - E2D4H1/1

380VAC

10L

440

717

YBZ - E2B4H1/1

6L

300

577

YBZ - E2C4H1/1

8L

370

647

YBZ - E3D4H1/3

3mL/r

10L

440

717

YBZ - E3E4H1/1

12L

540

817

YBZ - E3D4I1/1

3KW

3ml/r

20MPa

10L

440

717

YBZ - F2.1C3G1/1

220VAC

1.5KW

2.1ml/r

8L

370

647

YBZ - F2.5D4H1/1

380VAC

2.2KW

2.5ml/r

10L

440

717

Remark: 1. Please go to page 38 or consult our sales engineer for the different pump displacement, motor power or tank capacity.
2. 60HZ motors with CSA or UL certification are available upon request.

Special notes


1.The power unit is of S3 duty, which can only be worked intermittently, ie., 1minute on and 9 minutes off.
2.Clean all the hydraulic parts concerned before mounting the power unit.
3.Viscosity of the oil shoud be 15~68 cst,and the oil should be clean and free of impurities,N46 hydraulic oil is recommended.
4.The power unit should be mounted vertically.
5.Check the oil level in the tank after the first star of the power unit.
6.Oil changing is required after the initial 100 operation hours, afterwards once every 3000 hours.