Power Units For Double-scissors Lift 2
Power Units For Double-scissors Lift 2
General Description
Equipped with the zero leakage double-check solenoid valves, this power unit fulfils the complete separation of the two independent circuits,which are respectively for the main platform and subordinate platform of the double scissors lift. By increasing the number of the solenoid vavles,it is easy to get more independent circuits, which are used to control the corresponding cylinders.
Outline Dimension
Model Specifications
Model
| Motor Volt
| Motor power
| Rated Speed
| Displacement
| System pressure
| Tank Capacity
|
YBZ5-F2.7C3G30/LBCEN1 | 220VAC | 1.5KW | 1400rpm | 2.7mL/r | 22MPa | 8L |
YBZ5-F3.2E3G30/LBCEN1 | 3.2mL/r | 20MPa | 12L |
YBZ5-F2.5F3H30/BCCEN1 | 2.2KW | 2800rpm | 2.5mL/r | 18MPa | 14L |
YBZ5-E3.2G3H30/LCCEN1 | 3. 2 mL/r | 15MPa | 16L |
YBZ5-D4.2G3H30/LCCEN1 | 4. 2 mL/r | 10MPa | 16L |
YBZ5-F2.7H4I30/BCCEN1 | 380VAC | 3KW | 2.7mL/r | 20MPa | 20L |
YBZ5-F3.2I4I30/LCCEN1 | 3.2mL/r | 18MPa | 22L |
YBZ5-E3.7J4I30/LCCEN1 | 3.7mL/r | 16MPa | 25L |
Remark:1. Please go to page 38 or consult our sales engineer for the different pump displacement, motor power or tank capacity.
2. 60HZ motors with CSA or UL certification are available upon request.
Special Notes
1.The duty of this power unit is S3, i.e., 30 seconds on and 270 seconds off.
2.Clean all the hydraulic parts concerned before mounting the power unit.
3.Viscosity of the hydraulic oil shoud be 15~68 cst,which should also be clean and free of impurities.N46 hydraulic oil is recommended.
4.This power unit should be mounted vertically.
5.Check the oil level in the tank after the first start of the power unit.
6.Change the oil after the first 100 hours of running the power unit, then change the oil every 3000 hours.