DC Motor Pump Group 2
General Description
This motor pump consists of a 4.5±DC motor, a CBR gear pump with built-in relief valve and check valve. As a hydraulic power unit, it is widely used in hydraulic systems on machines.
Order Code
Outline Dimension
Technial Date
Model
| Motor Volt
| Motor Power
| Displacement
| Speed
| Operating pressure
| Dimension(mm) |
M | L |
DMP-RE1.8-1WWU-A | 12V | 1.5KW | 1.8mL/r | 2500rpm | 16MPa | 65.3 | 299.3 |
DMP-RE2.1-2AWU-A | 24V | 2KW | 2.1mL/r | 300.3 |
DMP-RE2.1-2MWU-A | 2.2KW |
DMP-RD2.6-2MWU-A | 2.6mL/r | 10MPa | 71.8 | 301.8 |
DMP-RE2.1-9MWU-A | 48v | 2.1mL/r | 16MPa | 65.3 | 300.3 |
Special Notes
1.The power unit is of S3 duty, which can only work intermittently and repeatedly,ie., 1minute on and 9 minutes off.
2.Clean all the hydraulic parts concerned before mounting the power unit.
3.Viscosity of the oil shoud be 15~68 cst,and the oil should be clean and free of impurities,N46 hydraulic oil is recommended .
4.The pump station should be mounted horizontally.
5.The relief valve pressure is preset about 25% higher than the operating pressure.