LFS-03 can be is applied to detection of positive or negative pressure. It can be used as a gauge or differential pressure switch with almost no hysteresis. If 2 switch points are required, 2 pressure switches with different calibrations should be employed.
The method of fixing the tab terminals to the switch body does not allow for absolute air sealing. The switch is therefore not recommended for applications where the static vacuum has to be maintained. However, special models with additional pressure spring which allow for the vacuum to be connected to the pressure inlet side are available on request.
Specification
| Model | LFS-03 |
| Electrical Function | 1 pole NO |
| Switch Rating | 1 pole NO: |
| Temperature | Ambient: -10 to +85? |
| Electrical Connections | Tab terminals 6.4 x0.8 mm |
| PressureRange | Pressure: +15 to +2500 mbar |
| Sample Line Connections | Pressure and vacuum: Inlet 4.0 or5.5 mm(up to 500 mbar) |
| Switch hysteresis | Almost no hysteresis |
| Max. working pressure | 3000 mbar |
| Medium | Nonhazardous gas only |
| Fixing Methods | Plastics clips (version with inlet only) |
| Materials | Lower body: PA 66 |
| Upper body: PA 66 | |
| Adjust. screw: PA 66 | |
| Contact carrying parts: Brass Silver plated (gold plating on request) |
Conversion: 1mbar = 100 Pa 1 in/H2O= 249 Pa
,