Detection principle | German EC Sense solid polymer electrochemical detection technology |
order no | TB600B-WQ-AQS-10 |
Detection of gas | Smell smell, sulfide gas, most volatile organic gas, toxic or harmful gases |
Detection range | 0 to 10 PM. The maximum overload range 20 PPM |
minimum detection limit | 0.01 PPM. Of resolution of 0.001 PPM |
Full range of accuracy error (typical) | 0 PPM ~ 5 PPM error of plus or minus 2 ~ 5% (5 PPM as the only unit) |
5 PPM ~ 10 PPM error of plus or minus 5% (10 PPM as the only unit) |
Warm-up time (typical) | Store under the clean air for the first time to electricity < 120 seconds |
< 3 seconds (t-50: < 40 seconds: T90: < 80 seconds: T100: < 180 >) |
Response time (typical) | < 3 seconds (t-50: < 40 seconds: T90: < 80 seconds: T100: < 180 >) |
Back to zero time (typical) | Below 10 PPM back to zero (0.03 PM) < 40 seconds (need ventilation relatively clean environment next time zero Back to zero) |
Below 5 PPM back to zero (0.03 m) < 80 seconds (need ventilation relatively clean environment next time zero) |
Calibration material | Sulfide, VOC, CO and other harmful gas mixture calculated calibration |
Note: the smaller the scale range, the detection accuracy is higher, the outrange user is not recommended to use, we can according to customer requirements range calibration |
Sensor life expectancy | Relatively clean air, temperature 0 to 25 ℃, 30-70% humidity environment more than 3 years (often exposed to corrosive gas, high temperature environment < 20% low humidity environment, sensor life decreases) |
AQS indoor environment air quality | 0-0.5 parts per million (fresh air); 0.5 2 PPM (trace pollution) |
2-5 PPM (light pollution); 5-10 PPM (moderate pollution); 10 PPM (severe pollution, should be quick to evacuate) |
Note: only for reference use empty inside and outside the living environment air pollution, not as a qualitative or quantitative measure of toxic gases |
Relative error of temperature | Plus or minus 0.2 ℃ (typical) |
Relative humidity of the error | Plus or minus 2% (typical) |
output signal | Digital signal (3.3 level UART communication protocol see after) |
The interface definition: VCC - red, designed.the GN - black, RX - yellow, TX - green |
Baud rate: 9600 bits: eight stop bit: 1 |
To get the data command | Communication points and take the initiative to upload and quiz, after power on default for question and answer mode, you can use the instructions for the two to get the data after the command or power switch power consumption mode back to q&a mode |
Power cuts or switch mode power consumption after recovery for question and answer mode |
See page after this document |
Working voltage | 4.5-5.5V DC |
Working current | 5V DV@5mA |
Power consumption | 25mW@5mA |
Repeatability (typical) | Full scale 10 PPM plus or minus 1% to the normal range |
Working temperature | -40~55℃ |
best working temperature | 20~35℃ |
Working humidity | 10%-95%RH |
Best work humidity | 40~70%RH |
Pressure of work | Atmospheric pressure±10% |
Circuit board size | 23 x25. 5 x10. 2 mm (with sensor) |
Circuit board size | 23 x25. 5 x4. 85 mm (without sensor) |
weight of | 3.1g |
Signal lines | The standard length see chart, if you have special requirements can be customized |