PRODUCTION INTRODUCTION
The product is composite with solid dielectric insulted pole, permanent magnetic actuating device or motor actuating device, control unit, current transformer and vacuum interrupter and voltage sensor. Except the control unit is a single device, the others are combined together, compact frame, flexible design, easy to operate.
| Items | Unit | ZW32-12/400 | ZW32-12/630 | ZW32-12/1250 | |
| Rated voltage | kV | 12 | |||
| Rated current | A | 400 | 630 | 1250 | |
| Rated short circuit breaking current | kA | 20/25 | |||
| Rated short circuit making current (peak value) | 50 | ||||
| Rated peak withstand current | 50 | ||||
| Rated short circuit withstand current | 50 | ||||
| Rated short circuit duration | S | 4 | |||
| Rated insulating level | 1 minimum PF withstand voltage | Phase to phase, to ground 40, fracture 48 | |||
| Lightning impolse withstand voltage peak value | phase to phase, to ground 75, fracture 85 | ||||
| Rated sequence of operations | O-0.3s-CO-180s-CO | ||||
| Rated short circuit current breaking time | 30 | ||||
| Mechanical endurance | 10,000 | ||||
| Rated operation voltage (opening, closing coil) | V | DC220,110 AC220,110 | |||
| Moving and fixed contact allowance wearing collation thickness | mm | 3 | |||
| Over-current release nominal current | 5 | ||||
| Current transformer ratio | A | 200/5,400/5 and 600/5 | |||
| 1 minimum second PF withstand voltage | mm | 2 | |||
| Over current tripping current | A | 5 | |||
| Rated single capacitor bank switching current | kA | 630 | |||

Detail Functions:
+with Instantaneous over current protection, definite time over current protection and over current protection, over current,three-stage current protection, low voltage component block, composite voltage component block or direction component block is available for each section;
+with zero sequence over current protection, E/F, SEF, with directional model for selection;
+with Manual closed accelerating protection, the breaker will trip fast when it's closed in fault, and it will trip and lockout,close operation;
+with cold load protection;
+with hot-line-tag protection;
+with two stage negative sequence over current protection;
+with frequency protection and frequency slip protection;
+with over-voltage protection ;
+with under-voltage protection ;(optional)
+with residual voltage protection ;
+with frequency protection ;
+with relay for additional transformer protection high temperature input; (optional/definable)
+with relay for additional transformer protection heavy gas input ; (optional/definable)
+Event record, Real-time sync, Real time checking,