Membership
Help
Shenzhen ZLPOWER Electronics Co., Ltd.
Shenzhen ZLPOWER Electronics Co., Ltd.
RM series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Features:
*Output voltage, frequency parameter and bypass function can be set via the LCD display.
*LED +LCD display Detailed Real-Time UPS Status and parameters.
*True online double conversion technology with advanced microprocessor control
*Advanced MCU microprocessor control technology, ensure long life reliability.
*Rack mount 19”design to save space
*Excellent Protection against over voltage, over load, over current, over charge and so on.
*Input L and N lines reverse wiring detection, Auto start when AC back.
*DC start function, Input PFC revise function.
*Smart RS232 communication with monitoring software.
*Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
*Rack mount battery pack to extend backup time.
Model | RM6K-C | RM6KL-C | RM10K-C | RM10KL-C | |
Rated Power | VA/W | 6KVA/4800W | 6KVA/4800W | 10KVA/8KW | 10KVA/8KW |
Input | Phase | Single Phase with Ground | |||
Nominal Voltage | 220/230/240Vac | ||||
Voltage Range | 176 ~ 276VAC | ||||
Frequency Range | 46 ~ 54Hz | ||||
Power Factor | 0.98 | ||||
Connection | Terminal Block | ||||
Output | Phase | Single Phase | |||
Voltage | 110/115/120Vac or 220/230/240VAC± 1% | ||||
Frequency | 46~54Hz (Line mode) | ||||
50Hz ± 0.05Hz ( Battery mode) | |||||
Waveform | Pure Sine Wave | ||||
Overload Capability | 105%~130% for 10 min.,130% for 1 min. | ||||
Current Crest Ratio | 3:01 | ||||
Connections | IEC320-10A * 4 ď˝nd Terminal Block | ||||
Bypass | Automatic Transfer | on overload and UPS failure | |||
Before UPS Power-on | Yes | ||||
Voltage Range | 176 ~ 261VAC | ||||
Transfer Time | Zero | ||||
LED indicators | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | ||||
Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | ||||
Communications | RS-232 Serial Interface | ||||
Intelligent Slot; | |||||
OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) | |||||
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | ||||
Environmental | Operating Temperature | 0 ~ 40°C | |||
Operating Humidity | 20 ~ 90% non-condensing | ||||
Main Unit | Net Weight (Kg) | 17.70 | 18.30 | 19.70 | 20.30 |
Dimensions (LxWxH) mm | 484*653*134 (3U) | ||||
Battery Pack | Type | External Battery Pack | |||
Nominal DC Voltage | 192VDC | ||||
Battery Numbers & Capacity | 16pcs*12V 7AH | External Battery Pack | 16pcs*12V 7AH | External Battery Pack | |
Backup Time (Full load) | 4 min | Depending on the capacity of external battery packs | 3 min | Depending on the capacity of external battery packs | |
Recharge Time | 5hrs to 90% | 5hrs to 90% | |||
Charging Current (Max.) | 2A | 5A/7A±1A | 2A | 5A/7A±1A | |
Charging Voltage | 219.50VDC±1% | ||||
Net Weight (Kg) | 44.50 | --- | 44.50 | --- | |
Dimensions (LxWxH) mm | 484*621*134 (3U) | --- | 484*582*134 (3U) | --- | |