ZMCT116C Current Transformer
Small size,high accuracy,good consistency,for current and power measurement
Structural parameters:

Remarks: Primary input: straight- through type( make the measured circuit be through the hole)
Secndary output:1、2pin empty pins: 3、4pin
Front view Bottom view
The main technical parameters
Model | ZMCT116C |
input current | 0~40A(sampling resistor 50Ω) |
Rated output current | 2.5mA at input 5A |
turns ratio | 2000:1 |
phase angle error | ≤20'(input 1A,sampling resistor 50Ω) |
current range | 0~40A(sampling resistor 50Ω) |
linearity | 0.2%(5%dot~120%dot) |
Permissible error | -0.2%≤f≤+0.2%(input 1A,sampling resistor 50Ω) |
isolation voltage | 4500V |
application | current and power measurement |
Encapsulation | Epoxy |
installation | PCB mounting(Pin Length>3mm) |
operating temperature | -40℃~+85℃ |
Direction for use

Figure Ⅰ FigureⅡ
1. ZMCT116C used for measurement. Typical usage is shown in Figure 1 and Figure 2. R is a sampling resistor.
2. Empty pin can not be grounded.