6.35/11kv aerial bundle cable MV ABC cable 3x185+1x95sqmm CONSTRUCTION
1. Conductor The phase conductor is round compacted stranded H68 aluminum Bs2627.
2. Conductor shield Extruded layer of semiconducting compound.
3. Insulation XLPE (cross-linked polyethylene) rating is 91.C.
4. Insulation screen
Non-metallic part: an extruded layer of semiconductor compound.
Metal part: Copper tape shield (SCT).
5. Core wire identification color Red, yellow and blue tape should be used between the non-metallic and metal parts of the insulation
screen.
6. Diaphragm polypropylene laminated tape.
7. Outer sheath PVC type sT2 conforms to IEC 61512 black. The outer sheath should be stamped with corresponding l, 2, 3 red, yellow and blue phases.
8. Support wire Support wire should include stranded galvanized steel wire
9. Assembly Three ×LPE insulated copper wire shielded single-core cables are wound on the galvanized steel wire in a right-hand (Z) twist.
6.35/11kv aerial bundle cable MV ABC cable 3x185+1x95sqmm Technical data
Phase conductor
| Nominal cross-sectional area | mm2 | 50 | 70 | 95 | 120 | 150 | l85 | 241 |
| Number of cores | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
| Minimum number of wires | 6 | 12 | 15 | 15 | 15 | 30 | 30 | |
| Nominal diameter of conductor | mm | 8.l | 9.7 | 11.5 | 12.9 | l4.3 | 16.1 | l8.4 |
| Nominal thickness of ×LPE insulation | mm | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 | 3.4 |
| Metallic screening approx. thickness of copper tape | mm | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
| Nominal thickness of outer sheath | mm | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| Nominal diameter over sheathing | mm | 23.0 | 24.6 | 26.3 | 27.8 | 29.2 | 30.9 | 33.3 |
| Max. dc resistance at 20°C | ohm.km | 1.64l | 1.443 | 0.320 | 0.253 | 0.206 | 1.l64 | 0.125 |
| Earth fault current carrying capacity of metallic screen at | ||||||||
| -1 second ( 1 Core ) | kA | 1.57 | 1.72 | l.88 | 2.01 | 2.l4 | 2.30 | 2.52 |
| -3 seconds ( 1 Core ) | kA | 0.90 | 0.99 | l.18 | 1.16 | 1.23 | 1.33 | l.45 |
Messenger - Galvanized steel wire
| Nominal cross-sectional area | mm2 | 50 | 50 | 50 | 50 | 50 | 50 | 50 |
| Stranding | No..mm | 7.3.l5 | 7.3.l5 | 7.3.l5 | 7.3.l5 | 7.3.l5 | 7.3.l5 | 7.3.l5 |
| Direction of the outermost layer | Right-hand ( Z ) | |||||||
| Overall diameter | mm | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 | 9.45 |
| Minimum breaking load | kg | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 | 6270 |
Completed cable
| Approx. overall diameter | mm | 55 | 59 | 62 | 65 | 67 | 71 | 75 |
| Approx. weight of cable | kg.km | 2541 | 2891 | 3300 | 3660 | 4141 | 4541 | 5290 |
| Packing length | m.drum | 500 | 500 | 500 | 500 | 500 | 500 | 500 |