Jiangsu Grand Cable Co., Ltd.
Jiangsu Grand Cable Co., Ltd.
Description
Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath.
Small overall diameter - concentric construction (SNE - Seperate Neutral Earth).
Lower mass - due to smaller diameter - no steel wire armour.
Increased safety - reliable earthing.
Improved reliability -UV stable sheath and core insulation andwater blocked.
Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer.
Easy strip with nylon ripcord.
Applicable Standard
SANS 1507-6
Dimension Characteristics
Electrical Properties
| Cable Size (mm²) | 10 | 16 |
| Phase Conductor Resistance (Ohm/km) DC @20°C | 1.90 | 1.20 |
| Earth Size (mm²) | 7.5 | 10 |
| Netural Size (mm²) | 10 | 16 |
| Phase Core Impedance (Z) (Ohm/km) | 2.34 | 1.47 |
| Current Rating *(A) | 50 | 70 |
| Pilot Core (No. X OD) Soild (mm) | 2 x 1.13 | 2 x 1.13 |
*Note: - In air, with 30 °C ambient with maximum conductor temperature 90 °C
Mechanical Properties
| Cable Size (mm²) | 10 | 16 |
| Phase Conductor (No. X OD) (mm) | 7 x 1.35 | 7 x 1.67 |
| Nominal Insulation Thickness (mm) | 1.0 | 1.0 |
| Netural Conductor (No. X OD) (mm) | 7 x 1.33 | 7 x 1.76 |
| Earth Conductor (No. X OD) (mm) | 3 x 1.78 | 3 x 2.20 |
| Nominal Sheath Thickness (mm) | 1.6 | 1.6 |
| Approximate Cable OD (mm) | 12.8 | 14.5 |
| Approximate Cable Mass (kg/km) | 320 | 485 |




Description
Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath.
Small overall diameter - concentric construction (SNE - Seperate Neutral Earth).
Lower mass - due to smaller diameter - no steel wire armour.
Increased safety - reliable earthing.
Improved reliability -UV stable sheath and core insulation andwater blocked.
Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer.
Easy strip with nylon ripcord.
Applicable Standard
SANS 1507-6
Dimension Characteristics
Electrical Properties
| Cable Size (mm²) | 10 | 16 |
| Phase Conductor Resistance (Ohm/km) DC @20°C | 1.90 | 1.20 |
| Earth Size (mm²) | 7.5 | 10 |
| Netural Size (mm²) | 10 | 16 |
| Phase Core Impedance (Z) (Ohm/km) | 2.34 | 1.47 |
| Current Rating *(A) | 50 | 70 |
| Pilot Core (No. X OD) Soild (mm) | 2 x 1.13 | 2 x 1.13 |
*Note: - In air, with 30 °C ambient with maximum conductor temperature 90 °C
Mechanical Properties
| Cable Size (mm²) | 10 | 16 |
| Phase Conductor (No. X OD) (mm) | 7 x 1.35 | 7 x 1.67 |
| Nominal Insulation Thickness (mm) | 1.0 | 1.0 |
| Netural Conductor (No. X OD) (mm) | 7 x 1.33 | 7 x 1.76 |
| Earth Conductor (No. X OD) (mm) | 3 x 1.78 | 3 x 2.20 |
| Nominal Sheath Thickness (mm) | 1.6 | 1.6 |
| Approximate Cable OD (mm) | 12.8 | 14.5 |
| Approximate Cable Mass (kg/km) | 320 | 485 |