BA47-29 are intended for protecting distribution and group systems having different loads:
- electric appliances, lighting – V characteristic switches;
- drives with moderate starting currents (compressor, fan group) - C characteristic switches;
- drives with high starting currents (hoisting mechanisms, pumps) - D characteristic switches;
Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public buildings.
>> Advantages
· Two types of short circuit protection.
· Wide range of operating temperatures from –40 to +50° С.
· Updated wider engagement lever with improved contact area.
· Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.
| MCB DA47-29 | ||||||
| For protection of general power distribution (IEC/EN 60898-1) | ![]() | ![]() | ![]() | ![]() | ||
| Poles | 1P | 2P | 3P | 4P | ||
| Electrical performance | ||||||
| Functions | short circuit protection,overload protection,isolationg,control | |||||
| Rated frequency f(Hz) | 50-60Hz | |||||
| Rated working voltage Ue V AC | 230/400 | 400 | ||||
| Rated current In (A) | 6,10,16,20,25,32,40,50,63 | |||||
| Rated insulated voltage Ui(V) | 500 | |||||
| Impulse withstand voltage Uimp(kV) | 4 | |||||
| Instantaneous tripping type | BA47-29 | B/C/D | ||||
| Rated short circuit Icn(kA) | BA47-29 | 4.5 | ||||
| Release type | Thermal magnetic type | |||||
Service life(O~C) | Mechanical | Actual value | 20000 | |||
| Standard value | 4000 | |||||
Electrical | Actual value | 8000 | ||||
| Standard value | 4000 | |||||
| Connection and installation | ||||||
| Protectiom degree | IP20 | |||||
| Wire mm² | 1~35 | |||||
| Working temperature | -5 ~+40℃ | |||||
| Resistance to humidity and heat | Class 2 | |||||
| Altitude above sea | ≤2000 | |||||
| Relative humidity | +20℃ , ≤90% ;+40℃ , ≤50% | |||||
| Pollution degree | 2 | |||||
| Installation environment | Avoid obvious shock and vibration | |||||
| Installation class | Class Ⅱ , Class Ⅲ | |||||
| Mounting | DIN35 rail | |||||
| Combination with accessories | ||||||
| Auxiliary contact | Yes | |||||
| Alarm contact | Yes | |||||
| Shunt release | Yes | |||||
| Undervoltage release | Yes | |||||
| Auxiliary contact+Alarm contact | Yes | |||||
| Dimensions(mm) (WxHxL) | a | 17.5 | 35 | 52.5 | 70 | |
b | 80.2 | 80.2 | 80.2 | 80.2 | ||
c | 76.5 | 76.5 | 76.5 | 76.5 | ||