Membership
Help
Flagsun (Suzhou) New Energy Co.,Ltd
Flagsun (Suzhou) New Energy Co.,Ltd
340w-360w BIPV solar panels
| Rated Maximum Power at STC | 340W | 345W | 350W | 355W | 360W |
| Maximum Power Voltage (Vmp) | 37.1V | 37.5V | 37.8V | 38.7V | 38.4V |
| Maximum Power Current (Imp) | 9.26A | 9.28A | 9.29A | 9.17A | 9.39A |
| Open Circuit Voltage ( Voc) | 47.0V | 47.2V | 47.3V | 47V | 48.3V |
| Short Circuit Current (Isc) | 9.81A | 9.82A | 9.82A | 9.69A | 9.84A |
| Module Efficiency | 17.04% | 17.29% | 17.54% | 18.3% | 18.37% |
| Power Tolerance | 0~+3% | 0~+3% | 0~+3% | 0~+3% | 0~+3% |
| STC: Irradiance 1000W/m², Module Temperature 25°c, Air Mass 1.5 | |||||
| Mechanical Parameters | |||||
| Cell Type | Mono-crystalline 156x156mm (6inch) | ||||
| No. of Cells | 72 (6x12) | ||||
| Dimension | 1956x990x40/45/50mm | ||||
| Glass | 3.2mm, High Transmission, Low Iron, Tempered Glass | ||||
| Junction Box | IP65&IP67 Rated | ||||
| Output Cable | Section Size: 4mm² , Length: 900mm | ||||
| Frame | Anodized Aluminum Alloy | ||||
| No. of Bypass Diodes | 3&6 | ||||
| Connector | MC4 Compatible | ||||
| Working Conditions | |||||
| Maximum System Voltage | DC 1000V(IEC) / 1500V(IEC) / 600V(UL) | ||||
| Operating Temperature | -40°c~+85°c | ||||
| Maximum Series Fuse | 15A | ||||
| NOCT | 45±2°c | ||||
| Application Class | Class A | ||||
| Temperature Coefficient | |||||
| Temperature Coefficient of Pmax | -0.40%/°c | ||||
| Temperature Coefficient of Voc | -0.30%/°c | ||||
| Temperature Coefficient of Isc | +0.05%/°c | ||||
Building Integrated Photovoltaic (BIPVBuilding Integrated Photovoltaic), that is, laying solar photovoltaic panels outside the building.
It is an important form of developing and applying solar power generation.
The basic principle and characteristics of BIPV
A typical photovoltaic building integrated system is shown in Figure 1. The system is a household rooftop photovoltaic system, and the solar photovoltaic array is laid on the roof.
The generated DC power is boosted by the primary DC-DC converter and tracked at the maximum power point, and then converted into the same frequency and phase with the grid through the inverter device.
The AC power is connected to the grid, and most of the power generated by it is consumed by the electrical equipment loaded in the building, and the excess power is injected into the power grid, while the photovoltaic power generation output
In lesser cases, the loads in the building can draw power from the grid.
Advantages
(1) The use of photovoltaic power generation can reduce the emission of carbon dioxide and sulfur dioxide, and help to build a low-carbon, energy-saving and environmentally friendly power supply system;
(2) The photovoltaic modules are on the surface of the building and do not occupy the ground space, which is especially important for urban buildings with dense population and expensive land resources
(3) Due to the high integration of light-needle cells and building materials, the construction and installation costs are reduced, which not only reduces the overall cost of the building, but also increases the artistic charm of the building;
(4) Building-integrated photovoltaics (BIPV) mainly supply power for near-end loads (in most cases, the electrical equipment inside the building), which reduces the load's dependence on the power grid, reduces the transmission loss on the power supply line, and increases the reliability of power supply. ;
(5) Photovoltaic power generation produces more power in summer and during the day. For photovoltaic systems in factories and office buildings, this feature can be used to reduce peak power demand;
(6) The photovoltaic cells on the building surface absorb solar energy and convert it into electrical energy, which reduces the heat gain of the wall or roof, helps to reduce the thermal load of the building's indoor air-conditioning unit, and plays a role in heat insulation;
(7) The photovoltaic power generation system has both a DC part and an AC part, which is beneficial to directly connect to the emerging DC microgrid in combination with the DC conversion technology, and directly supply power to the DC load, thereby reducing the conversion link and improving the efficiency.