H-62B Spoke Load Cell

Electrical connection and Dimensions :( dimension unit: mm)

Technical Specifications
Specifications: | ||||
capacity | kg | 5、10、20、30、50、100、200、300、500 | ||
safe overload | %FS | 120 | ||
ultimate overload | %FS | 150 | ||
rated output | mV/V | 1.0 ± 0.2 | ||
excitation voltage | Vdc | 10 | ||
combined error | %FS | ± 0.3 | ± 0.5 | ± 1 |
zero unbalance | %FS | ± 2 | ||
non-linearity | %FS | ± 0.3 | ± 0.5 | ± 1 |
hysteresis | %FS | ± 0.3 | ± 0.5 | ± 0.5 |
repeatability | %FS | ± 0.1 | ± 0.2 | ± 0.2 |
creep | %FS/30min | ± 0.1 | ± 0.2 | ± 0.3 |
input resistance | Ω | 350 ± 10 | ||
output resistance | Ω | 351 ± 4 | ||
insulation resistance | M Ω | ≥ 5000 @ 50 Vdc | ||
operating temperature range | ℃ | -10 ~ +60 | ||
compensated temperature range | ℃ | -10 ~ +40 | ||
temperature coefficient of SPAN | %FS/10℃ | ± 0.05 | ± 0.1 | ± 0.2 |
temperature coefficient of ZERO | %FS/10℃ | ± 0.05 | ± 0.1 | ± 0.2 |
Electrical connection:
Excitation+ red Excitation- black Signal+ green Signal- white
Four-core shielded cable with polyethylene.
Cable diameter :¢4mm