Specification parameter | Order number |
Basic model,32MB program data space,64KB power down hold data,55M expansion bus,24VDC power supply, 2*RS485 ports,1*EtherNET port,1*USB port,1*CAN port,1*EtherNET/EtherCAT port: supports visual WebVisu and OPC UA slave station, support EtherNet/IP master station, support MODBUS(RTU/TCP) master/slave, support single-axis motion,Maximum number of racks:4 (including local racks),support up to 128 EtherCAT slave stations, support CODESYS programming platform SP18 version. | CTH3 C35-003S2 |
Product model | C35-03 | ||||||||
Order numbe | CTH3 C35-003S2 | ||||||||
Physical characteristics | |||||||||
Size (WxHxD) | 34×115×101.6 mm | ||||||||
Power loss | 19.2W | ||||||||
Power supply characteristic | |||||||||
Rated input voltage | 24V DC | ||||||||
Input voltage range | 20.4V~28.8V DC | ||||||||
Input current | 0.8A | ||||||||
Polarity reverse protection | Yes | ||||||||
Bus power voltage | +5V DC | ||||||||
Bus power current | 1.6A | ||||||||
LED indicator characteristics | |||||||||
24V Power indicator (green) | On: 24VDC power supply is normal; Off: No 24VDC power supply. | ||||||||
SF Indicator (red) | On: The system is faulty. Off: no error. | ||||||||
BF indicator (red) | On: The bus is faulty. Off: no error. | ||||||||
RUN indicator (green) | On: The system is running. OFF: The system stops | ||||||||
STOP indicator (yellow | On: The system stops. Off: The system is running | ||||||||
Ethernet indicator | (Green) | On: Connect; Off: No connection | |||||||
(Yellow) | On: 100Mbps; Off: 10Mbp | ||||||||
CAN port indicator | (Green) | On: Connected; Off: Not connected | |||||||
(Yellow) | On: 100Mbps; Off: 10Mbps | ||||||||
Instruction performance | |||||||||
Bit instruction execution speed | 15ns | ||||||||
Floating point instruction execution speed | 45ns | ||||||||
Internal memory | |||||||||
User program space | 32M | ||||||||
Power off hold space | 64KB | ||||||||
Data storage specification | Zone I 32K, Zone Q 32K, zone M 512K | ||||||||
Integrated communication function | |||||||||
Bus interface | Support | ||||||||
USB port | 1 | ||||||||
| EtherNET port | 2(One of them is an EtherNET/EtherCAT switchable communication interface) | ||||||||
| RS485 port | 2 | ||||||||
| EtherCAT port | 1 | ||||||||
| CAN port | 1 | ||||||||
| EtherCAT port | |||||||||
Communication interface | 1*EtherCAT por | ||||||||
Baud rate | 100Mbps adaptive | ||||||||
Protocol type | EtherCAT Interface protocol | ||||||||
Maximum cable length per section | 100m | ||||||||
Maximum number of sites | Each master supports a maximum of 128 EtherCAT slave stations | ||||||||
Support function | Support distributed clock configuration, redundancy Settings | ||||||||
Support startup parameter configuration | |||||||||
Support PDO parameter configuration and mapping | |||||||||
| Support for bus cycle configuration, configure startup check vendor ID and product ID | |||||||||
Isolate | Yes | ||||||||
RS485 communication port | |||||||||
Number of communication interfaces | 2,PORT0,PORT1 | ||||||||
Communication protocol | Free port protocol (built-in MODbus-RTU protocol) | ||||||||
Free port baud rate | Ranges from 1.2Kbps to 115.2Kbps | ||||||||
Maximum cable length per section | Use isolation repeater: 1000m(115.2Kbps) 1200m(38.4 kbps) Isolation repeater not used: 50m | ||||||||
Maximum number of sites | 32 stations per segment, 126 stations per network. | ||||||||
Isolate | Communication port isolation | ||||||||
| CANopen port | |||||||||
Communication interface | CANopen | ||||||||
Maximum number of secondary sites | 32 | ||||||||
Protocol typ | CANopen DS301 standard protocol | ||||||||
Support function | Support automatic start CANopen Manager | ||||||||
| Support Optional slave polling | |||||||||
| Support starting the slave station | |||||||||
| Support NMT | |||||||||
| Support synchronous production | |||||||||
| Support synchronous consumption | |||||||||
| Support heartbeat generation | |||||||||
| Support activation time creation | |||||||||
Transmission rate (kbit/s) | 1000 | 800 | 500 | 250 | 125 | 50 | 20 | ||
Maximum length (m) | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 | ||
Isolate | Communication port isolation | ||||||||
| EtherNET port | |||||||||
Communication interface | 2*EtherNET ports (one of which is EtherNET/EtherCAT for switching communication) | ||||||||
Baud rate | 10/100Mbps adaptive | ||||||||
Protocol typ | CODESYS custom protocol, based on UDP and TCP(Ethernet programming and CPU support | ||||||||
Maximum cable length per section | 100m | ||||||||
Maximum number of connections for a site | UDP supports a maximum of 16 connections | ||||||||
Isolat | Communication port isolation | ||||||||
Programming Software | |||||||||
Programming package | CODESYS V3.5 (SP18 version) | ||||||||
Programming language | Programming language according to IEC61131-3: CFC/FBD/LD/IL/ST/SFC | ||||||||
Protection function | |||||||||
Power supply protection | The power supply terminal provides reverse protection and surge absorption functions | ||||||||
Interface protection | Lightning protection for communication ports | ||||||||
Local I/O scalability | |||||||||
Maximum number of racks | 4 | ||||||||
Maximum number of modules | Host rack: 11 (power module, CPU, trunk module, 8 signal modules) Slave rack: 10 (power module, trunk module, 8 signal modules) | ||||||||
Remote I/O expansion capability | |||||||||
CAN extended maximum number of master stations | 1 | ||||||||
CAN maximum number of slave stations | Each master station connects to a maximum of 32 CAN slave stations. | ||||||||
EtherCAT maximum number of extended slaves | Up to 128 EtherCAT slave modules , each EtherCAT slave module has a maximum of 8 signal modules | ||||||||
Supports motion control function | |||||||||
Motion control function | Do not support SoftMotion and CNC | ||||||||
Real-time clock | |||||||||
Power off hold | The power failure holding time is about 112 hours (typical value), and the power failure holding time can reach at least 1 year after the external battery is connected | ||||||||
Precision | Monthly deviation <60 seconds | ||||||||

Power interface definition
4-pin removable terminals with 3.81mm spacing | Symbol | Signal definition |
| L+ | +24V power supply |
M | +24V power ground | |
| Earth | |
-- | -- |
USB interface definition
USB interface | Bit number | Signal | Signal definition |
| 1 | V_BUS | +5V power supply |
2 | Data- | Data- | |
3 | Data+ | Data+ | |
4 | GND | Earth |
EtherNET/EtherCAT interface definition
RJ45 network port | Bit number | Signal | Signal definition |
| 1 | TX+ | Data sending end |
2 | TX- | Data sending negative end | |
3 | RX+ | Data receiving terminal | |
4 | TERM | -- | |
5 | TERM | -- | |
6 | RX- | Data receiving negative end | |
7 | TERM | -- | |
8 | TERM | -- | |
Connector housing | PE | Casing grounding | |
Green lindicator | As an indication of EtherNET/EtherCAT connection status | ||
Yellow indicator | As an indication of EtherNET/EtherCAT speed status | ||
CAN interface definition
RJ45 network port | Bit number | Signal | Signal definition |
![]() | 1 | CAN_H | Data sending end |
2 | CAN_L | Data sending negative end | |
3 | -- | -- | |
4 | -- | -- | |
5 | -- | -- | |
6 | -- | -- | |
7 | CAN_GND | CAN_GND | |
8 | -- | -- | |
Connector housing | PE | Casing grounding | |
Green lindicator | As an indication of the status of CAN data reception | ||
Yellow indicator | As an indication of the status of CAN data transmission | ||
RS485 interface Definition
The Port0 port uses two detachable terminals with a 3-pin spacing of 3.81mm | ||
6-bit detachable terminal | Signal | Signal definition |
| A0 | PORT0 port RS485 signal A |
B0 | PORT0 port RS485 signal B | |
SG | PORT0 port RS485 signal GND | |
A0 | PORT0 port RS485 signal A | |
B0 | PORT0 port RS485 signal B | |
SG | PORT0 port RS485 signal GND | |
Dip switch definition
Two-state switch | Bit number | Dip direction | Signal definition |
| ON | UP | System operation |
OFF | Down | System stop | |
DIP switch | Bit number | Symbol | Signal definition |
| 1 | Term-PORT0 | Terminal Resistance Switch 1 (PORT0) ON: terminal resistance; OFF: no terminal resistor |
2 | NC | Reserve | |
3 | NC | Reserve |