Membership
Help
Hangzhou Spring Electronics Co., Ltd.
Hangzhou Spring Electronics Co., Ltd.


CAT6 FTP 23AWG Data Lan Cable
These cables used in data transmission systems that work up to 200 Mbit/s. These cables are particularly preferred in the offices, buildings where many terminals are found. The outer sheath material of CAT6 FTP cable is PVC for indoor application; black PE is for outdoor application and HFFR is free flame retardant compound which has low smoke density and no toxic/corrosive gases during a fire.
Construction | ||||||||
Conductor: | 23 AWG Solid Bare Copper | |||||||
Pairs: | 4 Pairs | |||||||
Insulation: | 1.35 mm Skin-Foam-Skin | |||||||
Insulation Colors: | Blue-White/Blue,Orange-White/Orange | |||||||
Green-White/Green,Brown-White/Brown | ||||||||
Overall Shield | Individual Pair shield,Al/PET Foil,Foil face out | |||||||
Drain Wire | 0.40±0.005mm TC | |||||||
Rip Cord: | Cotton | |||||||
Out Jacket: | 8.0±0.2 mm PE | |||||||
Electrical Characteristics | ||||||||
Impedance | 4 - 100MHz 100±15 Ohms | |||||||
100 - 200MHz 100±22 Ohms | ||||||||
200 - 500MHz 100±32 Ohms | ||||||||
Max.Conductor DC | 8.7 Ohms/100m | |||||||
Res. unbalance (%) | Max. 2.5 | |||||||
Pair to Ground | 330 pF/100m | |||||||
Transfer Impendance | Max 10 mOhms/m @100Mhz | |||||||
Installation temp. | -30 - 50℃ | |||||||
Operation temp. | -20 - 75℃ | |||||||
Standard | ||||||||
IEC/ISO 61156-5; ANSI/TIA568C.2; ISOIIEC 11801 | ||||||||
Performance Characteristics | ||||||||
Frequency | RL (Min.) | Insertion Loss(Max.) | Propagation Delay (Max.) | Delay Skew(Max.) | NEXT (Min.) | PSNEXT (Min.) | ELNEXT (Min.) | PSELNEXT (Min.) |
MHz | dB | dB/100m | ns/100m | ns/100m | dB | dB | dB/100m | dB/100m |
1 | 20.0 | 2.1 | 570.0 | 45.0 | 74.3 | 72.3 | 67.8 | 64.8 |
4 | 23.0 | 3.8 | 552.0 | 45.0 | 65.3 | 63.3 | 55.8 | 52.8 |
10 | 25.0 | 6.0 | 545.0 | 45.0 | 59.3 | 57.3 | 47.8 | 44.7 |
16 | 25.0 | 7.6 | 543.0 | 45.0 | 56.2 | 54.2 | 43.7 | 40.7 |
20 | 25.0 | 8.5 | 542.0 | 45.0 | 54.8 | 52.8 | 41.8 | 38.8 |
31.25 | 25.0 | 10.7 | 540.0 | 45.0 | 51.9 | 49.9 | 37.9 | 34.9 |
62.5 | 21.5 | 15.4 | 539.0 | 45.0 | 47.4 | 45.4 | 31.9 | 28.9 |
100 | 20.1 | 19.8 | 538.0 | 45.0 | 44.3 | 42.3 | 27.8 | 24.8 |
200 | 18.0 | 29.0 | 537.0 | 45.0 | 39.8 | 37.8 | 21.8 | 18.8 |
300 | 17.3 | 36.4 | 536.0 | 45.0 | 37.1 | 35.1 | 18.3 | 15.3 |
400 | 17.3 | 43.0 | 536.0 | 45.0 | 35.3 | 33.3 | 15.8 | 12.8 |
500 | 17.3 | 45.3 | 536.0 | 45.0 | 33.8 | 31.8 | 13.8 | 10.8 |
Note: The above transmission performance tor the 100M, 20±2℃ under the conditions tested. | ||||||||