CKSG Three phase Shunt Reactor eletric inductor with copper wire for power capacitor correction

WENZHOU JUNKE ELECTRIC CO., LTD.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Miniature Circuit Breaker
Place of Origin
ZheJiang, WenZhou
Wrapped dry-type hollow reactorShunt reactorImprove the voltage distribution on long-distance transmission lines;3. Balance the reactive power in the line as much as possible when the load is light, to prevent the unreasonable flow of reactive power
A reactor is also called an inductor. When a conductor is energized, it will generate a magnetic field in a certain space occupied by it, so all electric conductors that can carry current have a general sense of inductance. However, the inductance of the energized long straight conductor is small, and the generated magnetic field is not strong. Therefore, the actual reactor is a solenoid with a wire wound, called an air-core reactor; sometimes in order to make this solenoid have a greater inductance, Then insert the iron core in the solenoid, called iron core reactor. Reactance is divided into inductive reactance and capacitive reactance. The more scientific classification is that inductors (inductors) and capacitive reactors (capacitors) are collectively referred to as reactors. However, since inductors existed in the past, they were called reactors. So now what people call a capacitor is a capacitive reactor, and a reactor specifically refers to an inductor.

APPLICATION

Shunt reactors are designed to be connected in parallel in inductive load systems, which can are used to absorb reactive power to reduce excessive voltage rise generated by line capacitance.
They are used where the inductive load is needed, such as:

  • In the long transmission lines and long overland cables.

  • In the test environments where inductive current is needed.

  • Reactive energy produced by UPS

Technical data

  • Rated voltage: (VAC)230V-690V
  • Rated frequency: (Hz)50/60
  • Power (Kvar):1Kvar-150Kvar
  • Inductance tolerance:0~+5%
  • Winding material:Aluminum/copper
  • Dielectric test:AC 50Hz, 3KV, 60s
  • Protection class:IP00
  • Insulation classH: 180℃
  • Temperature rise:125℃
  • ImpregnationResin: VPI
  • Cooling methodNatural air (AN)
  • Ambient temperature-25 to +50℃
  • Environ clim. And fire res.Class:.E1 C1 F0
  • Standard:IEC60076-6
  JUNKE, established in 2008, who specialized in research and design, manufacturing, and distribution of Ansi Socket Meter ,Electric Meter ,Generator Type Automatic Transfer Switch,Power Capacitor Correction,Power Factor Regulator ,Power energy analysis.Airc Circuit Breaker Which is widely used in Smart Grid Industry all covering distribution, Saving&Protecting& Metering Electicty, and Grid Power System and Generator Power Syestem. (Reactive Power and Generator power). We have one strong R&D and QC team continues to innovate new solutions, additions and extensions in the pursuit of not only meeting but exceeding market demand and to offer the best solutions for our customers.JUNKE's mission is to improve All Client Transformer Power Supply Quality, Reduce Power Loss, We provide reliable, accurate and customized Active power and Power Factor correction device for our customers.JUNKE values Enthusiastic by our work, we offer a quality personal and close service to our customersJUNKE sincerely supply you with high quality products and high effect service, willing to start deep cooperation with you soon after!!