Membership
Help
Poocca Hydraulic (Shenzhen) Co., Ltd.
Poocca Hydraulic (Shenzhen) Co., Ltd.
Closed axial piston pump A4VG


PAA4VG Variable Displacement Axial Piston Pump of swash plate design for hydrostatic closed circuit transmissions. Flow is proportional to drive speed and displacement and is infinitely variable. Output flow increases with swivel angle from 0 to its maximum value.
Name | A4VG Series Axial piston variable pump |
Series | Series 32 |
Sizes | 28 40 56 71 90 125 180 250 |
Nominal Pressure | 400 bar |
Maximum Pressure | 450 bar |
Operation Mode | Closed Circuit |

Size | NG | 28 | 40 | 56 | 71 | 90 | 125 | 180 | 250 | |||
Displacement | Vg max | cm3 | 28 | 40 | 56 | 71 | 90 | 125 | 180 | 250 | ||
boost pump (at p = 20 bar) | Vg Sp | cm3 | 6.1 | 8.6 | 11.6 | 19.6 | 19.6 | 28.3 | 39.8 | 52.5 | ||
Speed1) | maximum at Vg max | nnom | rpm | 4250 | 4000 | 3600 | 3300 | 3050 | 2850 | 2500 | 2400 | |
limited maximum2) | nmax | rpm | 4500 | 4200 | 3900 | 3600 | 3300 | 3250 | 2900 | 2600 | ||
intermittent maximum3) | nmax | rpm | 5000 | 5000 | 4500 | 4100 | 3800 | 3450 | 3000 | 2700 | ||
minimum | nmin | rpm | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | ||
Flow at nnom and Vg max | qv | L/min | 119 | 160 | 202 | 234 | 275 | 356 | 450 | 600 | ||
Power4) Dp = 400 bar | P | kW | 79 | 107 | 134 | 156 | 183 | 238 | 300 | 400 | ||
Torqu4) | Dp = 400 bar | T | Nm | 178 | 255 | 357 | 452 | 573 | 796 | 1146 | 1592 | |
Dp = 100 bar | T | Nm | 45 | 64 | 89 | 113 | 143 | 199 | 286 | 398 | ||
Rotary stiffness drive shaft | S | c | kNm/rad | 31.4 | 69 | 80.8 | 98.8 | 158.1 | 218.3 | 244.5 | 354.5 | |
T | c | kNm/rad | – | – | 95 | 120.9 | – | 252.1 | 318.4 | 534.3 | ||
A | c | kNm/rad | – | 79.6 | 95.8 | 142.4 | 176.8 | 256.5 | – | – | ||
Z | c | kNm/rad | 32.8 | 67.5 | 78.8 | 122.8 | 137 | 223.7 | 319.6 | 624.2 | ||
U | c | kNm/rad | – | 50.8 | – | – | 107.6 | – | – | – | ||
Moment of inertia for rotary group | JGR | kgm2 | 0.0022 | 0.0038 | 0.0066 | 0.0097 | 0.0149 | 0.0232 | 0.0444 | 0.0983 | ||
Maximum angular acceleration5) | a | rad/s2 | 38000 | 30000 | 24000 | 21000 | 18000 | 14000 | 11000 | 6700 | ||
Case volume | V | L | 0.9 | 1.1 | 1.5 | 1.3 | 1.5 | 2.1 | 3.1 | 6.3 | ||
Mass approx. (without through drive) | m | kg | 29 | 31 | 38 | 50 | 60 | 80 | 101 | 156 | ||
Center of gravity6) | X | mm | < 5 | < 5 | < 5 | < 5 | < 5 | < 5 | < 5 | < 5 | ||
Y | mm | 24 | 20 | 20 | 15 | 20 | 30 | 33 | 30 | |||
Z | mm | 105 | 112 | 106 | 135 | 145 | 160 | 180 | 203 | |||

Variable axial piston pump of swashplate design for hydro- static drives in closed circuit.
The flow is proportional to the drive speed and displacement.

The flow can be infinitely varied by adjusting the swashplate angle.
Flow direction changes smoothly when the swashplate is moved through the neutral position.
A wide range of highly adaptable control devices with different control and regulating functions, for all important applications.

Two pressure-relief valves are provided on the high-pressure side to protect the hydrostatic transmission (pump and mo- tor) from overload.
The high-pressure relief valves also function as boost valves.

The integrated boost pump acts as a feed pump and control pressure supply.
The maximum boost pressure is limited by a built-in low- pressure relief valve.
As standard with integrated pressure cut-off

The control method is:
LR – Power control
DR – Pressure control
HD – Hydraulic control, pilot-pressure related
EP – Electric control with proportional solenoid
Combination pumps A4VG + A4VG
A4VG | A4VG((2ndpump)3) | |||||||
(1st pump) | NG28 | NG40 | NG56 | NG71 | NG90 | NG125 | NG180 | NG250 |
NG28 | 453.8 | – | – | – | – | – | – | – |
NG40 | 464.1 | 480.4 | – | – | – | – | – | – |
NG56 | 485.8 | 502.1 | 522.8 | – | – | – | – | – |
NG71 | 524 | 539.3 | 560 | 597.2 | – | – | – | – |
NG90 | 528.4 | 544.7 | 565.4 | 602.6 | 610 | – | – | – |
NG125 | 554.3 | 571.6 | 592.3 | 629.5 | 644.9 | 670.3 | – | – |
NG180 | 604.8 | 620.1 | 640.8 | 678 | 692.9 | 718.3 | 762.8 | – |
NG250 | 652.3 | 661.6 | 682.3 | 719.5 | 745.9 | 771.3 | 815.8 | 854.8 |

1) 2nd pump without through drive and with boost pump, F00
By using combination pumps, it is possible to have indepen- dent circuits without the need for splitter gearboxes.
When ordering combination pumps, the type designations of the 1st and 2nd pumps must be linked by a "+".
Ordering example:
A4VG56EP3D1/32R-NAC02F073SP + A4VG56EP3D1/32R- NSC02F003SP
A tandem pump consisting of two equal sizes is permissible with- out additional supports assuming that the dynamic acceleration does not exceed maximum 10 g (= 98.1 m/s2).
We recommend the use of the 4-hole mounting flanges for size 71 and larger.
For combination pumps consisting of more than two pumps, the mounting flange must be rated for the permissible mass torque.

--Truck
--Industrial machineries
--Drilling machinery
--Heavy Machinery
--Mixer
--Construction machinery
--Hydraulic system
--Excavator
--Injection molding machine

REVIEW

Axial piston variable pump A4VG .Wear-resistant and high-termperature resistant.