Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
Compressed Air Gas Turbine Flow Meter
The Compressed Air Gas Turbine Flow Meter are robust and designed to perform on the highest level of accuracy. All these meters is the fact they comply with all international standards and are approved for custody transfer even with smallest possible installation length.
The actual flow sensor, an exchangeable cartridge, has a build-in multi stage flow conditioner enabling the meter to be installed with limited straight in- and outlet sections. All tested and proved according perturbation test as per international standards.


| Main Application | Natural Gas,LPG,Compressed Air,Nitrogen |
| Nominal Diameter | DN25-DN300 |
| Span | 2.5-6500m³/h |
| Rated Pressure | 1.6MPa~4.0MPa |
| Accuracy Level | ±1.5%R 1.0% Selectable |
| Repeatablility | ±0.1% |
| Range Ration | 1:10, |
| Material | Body/Rotor Support:SS304(SS316L optional) |
| Impeller:Double Phase Steel | |
| Shaft:Stainless Steel | |
| Bearing:Stainless Steel Ball Bearing | |
| Process Connection | Flange/Thread NPT/Wafer |
| Working Condition | Medium Temperature:-20℃~+80℃ |
| (Max Customize to150℃) | |
| Ambient Temperature:-20℃~+60℃ | |
| Rated Humidity:5%~90% | |
| Ambient Pressure:86KPa~106KPa | |
| Power | 24VDC |
| 3V 10AH lithium battery. | |
| Consumption | 24VDC power:<1W |
| Battery:≤1W,lifetime>3yrs | |
| Signal Output | Pulse,4-20mA,Switch Signal. |
| DIgital Communication | RS485,MODBUS,HART,PROFIBUS-DP |
| Signal wire joint | Hausman joint/Inner screw M20*1.5 or customized |
| Explosion Proof Grade | ExdIIBT6/ExiaIICT4 |
| Degree of Protection | IP65 or Higher |
Compressed Air Gas Turbine Flow Meter Product Feature
The temperature, pressure and flow of the tested gas can be detected, the flow can be automatically tracked and compensated, and the gas volume accumulation amount under the standard state (Pb = 101.325 KPa, Tb = 293.15 K) can be displayed; the temperature pressure value can be queried in real time
The flow range is wide (Qmax/Qmin ≥ 20:1), the repeatability is good, the precision is high (up to grade 1.0), the pressure loss is small, the initial flow rate is low, and the 0.6m3/h can be reached.
Multi-point nonlinear Correction of Intelligent instrument coefficient




Compressed Air Gas Turbine Flow Meter