CSPPM 14kPa Differential Pressure Transducer For Air Conditioning

Changsha Taihe Electronic Equipment Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Pressure Sensor
Place of Origin
HuNan, ChangSha
CSPPM 14kPa Differential Pressure Transducer For Air Conditioning

CSPPM 14kPa Differential Pressure Transducer For Air Conditioning

Description
Range:Overpressure<250 Pa:14 KPa
250 Up To 625 Pa >625Pa:35 KPa 69 KPa
High Light:

CSPPM Differential Pressure Transducer

,

14kPa Differential Pressure Transducer

,

14kPa Air Pressure Sensor

PPM-WCY66-P500A Heating, Ventilating and Air Conditioning Differential Pressure Transducer

Product Introduction:

PPM-WCY66-P500A pressure transducers sense differential or gauge (static) pressure and converts this pressure difference to a proportional electrical output. The 266 is offered with a high level 0-10 VDC and 0 -5 VDC output or a 4-20 mA output.

Used in Building Energy Management Systems, these transducers are capable of measuring pressures and flows with the accuracy necessary for proper building pressurization and air flow control.

low pressure transducers are available for air pressure ranges as low as 0 to ±50 Pa full scale up to 5 kPa full scale. Static accuracy is ±1% full scale in normal ambient temperature environments. The units are temperature compensated to less than ±0.06% FS/°C (±0.033% FS/oF) of thermal error over the temperature range of -18 to +65 °C (0oF to +150oF). utilizes an all stainless steel micro- tig welded sensor. The tensioned stainless steel diaphragm and insulated stainless steel electrode, positioned close to the diaphragm, form a variable capacitor. Positive pressure moves the diaphragm toward the electrode, increasing the capacitance.

Applications :

Heating, Ventilating and Air Conditioning (HVAC)

Energy Management Systems

Variable Air Volume and Fan Control (VAV)

Environmental Pollution Control

Static Duct and Clean Room Pressures

Fume Hood Control

Oven Pressurization and Furnace Draft Controls

Technical Parameters :

Accuracy RSS* (at constant temp.)±1.0 FS
Non-Linearity (BFSL)±0.98 FS
Hysteresis0.10 FS
Non-Repeatability0.05 FS
Thermal Effects
Compensated Range °C(°F)-18 to +65 (0 to +150)
Zero/Span Shift FS/°C(°F)±0.06 (±0.033)
Maximum Line Pressure69 kPa
Overpressure (DP on either side):
RangeOverpressure
<250 Pa14 kPa

250 up to 625 Pa

>625Pa

35 kPa

69 kPa

Warm-up Shift±0.1 FS Total
Position Effect***
RangeZero Offset ( FS/G
To 250 Pa0.6
To 1.3 kPa0.14
To 7.5 kPa0.06
Temperature
Operating* °C (°F)-18 to +65 (0 to +150)
Storage °C (°F)-40 to +85 (-40 to +185)
Physical Description
Case

Fire Retardent Glass Filled

Polyester (UL 94 V-0 Approved)

Electrical ConnectionScrew Terminal Strip
Pressure Fittings6.2 mm
Weight150 grams (5.3 oz.)
Electrical Data (Voltage)
Circuit3-Wire (Com, Out, Exc)
Excitation/Output*

12 to 30 VDC/VAC / 0 to10 VDC**

9 to 30 VDC/VAC / 0 to 5 VDC

9 to 30 VDC/VAC / 0 to 5 VDC**

Bidirectional output at zero
pressure:2.5 VDC (±50 mV)
Output Impedance100 Ohms
Circuit2-Wire
Output*4 to 20 mA**
Bidirectional output at zero
pressure:12 mA
Electrical Load0 to 800 Ohms
Minimum loop supply voltage (VDC) = 9 + 0.02 x (Resistance of receiver plus line).
Maximum loop supply voltage (VDC) = 30 + 0.004 x (Resistance of receiver plus line).

Dimensions in mm :

CSPPM 14kPa Differential Pressure Transducer For Air Conditioning 0

  CSPPM specialized in manufacturing and selling pressure sensors, transmitters, automation instrument and system. Based on Central South University (CSU), implemented the quality management system of ISO9001. declared several of national invention patents etc.