Welcome Customer !

Membership

XwbooInstrumentationTesting MachineOther Testing MachinesCT PT Analyzer
  • $item.Title
  • $item.Title

CT PT Analyzer

Wuhan Goldhome Hipot Electrical Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Other Testing Machines
Place of Origin
HuBei, WuHan
Tests for Current Transformer:)1)Excitation curve and parameters test)2)Turns ratio test)3)Ratio and phase error test)4)Polarity mark check)5)Winding resistance measurement)6)Secondary loop burden measurement)7)Error line curve test for protection CT)8)Transient CT parameters test)9)CT nameplate guess)10) Saturation hysteresis loop curve measurement
Introduction


HM404 CT PT Analyzer is used to measure all kinds of instrument transformer. The CT PT analyser can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. It also can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.


Application


Tests for Current Transformer:

1)Excitation curve and parameters test

2)Turns ratio test

3)Ratio and phase error test

4)Polarity mark check

5)Winding resistance measurement

6)Secondary loop burden measurement

7)Error line curve test for protection CT

8)Transient CT parameters test

9)CT nameplate guess

10) Saturation hysteresis loop curve measurement

Tests for Voltage Transformer:

1) Turns ratio test

2) Ratio error and phase angle error test

3) Polarity test

4) Secondary burden test

5) Winding resistance test

Applications of CT/PT Analyzer:

1)CT nameplate check

2)CT parameters check in work burden

3)CT transient parameters analysis

4)CT ratio and phase error calibration

5)PT routine test

(applied in transformer factory testing and applied in offshore wind power booster station testing)

(applied to test CT in the power distribution cabinet of the locomotive and applied in the500kv substation)


Technical Index


1) Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13

2) Power supply: AC220V±10%, 50/60Hz±10%

3) Voltage output: 0.1~180V (AC)

4) Current output: 0.001~5A(RMS)

5) Power output: 500VA

6) Maximum knee voltage measurement: 45KV


Range Error resolution

Current measurement

0~10A (automatically change range in 0.1/0.4/2/10A)

<±0.1%+0.01%FS


Voltage measurement

Range: 0~200V (automatically change range in 1V/10V/70V/200V)

Error: < ±0.1%+0.01%FS


Turns ratio measurement

1~5000

error<0.05%



5000~35000

error<0.1%


Phase measurement


±2min

0.01min

Winding resistance measurement

0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm)

< 0.2%RDG+0.02%FS

Maximum resolution: 0.1mΩ

Temperature measurement

-50~100 Celsius degree

<3 Celsius degree


CT Secondary burden

0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm)

<0.2%RDG+0.02%FS

Maximum resolution: 0.001ohm

PT Secondary burden

0~80kohm (automatically change range in 800ohm/8kohm/80kohm)

<0.2%RDG+0.02%FS

0.1ohm

PT ratio measurement

1~10000

<0.1%



10000~35000

<0.2%


7) PT ratio error measurement: Typical error <0.05%, Maximum Error<0.1%

8) PT phase angle measurement: maximum error < 3min

9)Make evaluation for test results according to selected standards

10) Make word report for test result

11) Make word reports one time for multi-group test records on the PC

12) Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test

13) Compare excitation curves with saved excitation curves in the same window

14) Memory capacity: >1000 groups test results

15)Working condition: temperature: -10℃~50℃; moist: ≤90%

16) Size: 485mm×356mm×183mm

17) Weight: <15kg

CT PT  Analyzer factory test


System Setup


The function of system setup command is to set the system running parameters such as system time, operator, and test address and so on. Panel as figure 1.1 will be showed on LCD when system setup button is clicked.

1

System run parameters in system setup panel have no effect in test control. All system run parameters only affect word test report. The name and definition of system run parameters are showed in table 1.2.

Table 1.2 System run parameters

Parameters name

Description

Tester ID

The identification number offered by manufacturer

Soft ID

Software version

Operator

Operator name in word test report

Test company

Test company in word test report

Test address

Test address in word test report

Report header

Document header in word test report

Report footer

Document footer in word test report

Other parameters in system setting panel are response for test control. The detailed information of those parameters is as table 1.3

Table 1.3 System setup parameters

Parameters name

Description

Automatic evaluation

1.If “Close evaluation procedure” is selected, Analyzer will offer parameter results of CT only when CT analysis test is end. Analyzer will not evaluate the test results according to selected standard

2.If “Evaluation in working burden only” is selected Analyzer will offer both parameter results of CT and evaluation results according to

selected standard when CT analysis test is end. But the evaluation results only include the parameters calculated in work burden.

3.If “Evaluation in both working and rated burden” is selected,

Analyzer will offer both parameter results of CT and evaluation results

according to selected standard when CT analysis test is end. The

evaluation results include the parameters calculated in both working and rated burden.

Excitation test control

Auto setting is factory setting. This parameter affects CT analysis and

ratio test. If measure saturation voltage automatically is selected,

Analyzer will select a special test frequency according to saturation value in excitation curve measurement. Otherwise Analyzer will not measure

saturation voltage before excitation curve test starts.

Warning: Please select automatic mode in most of time. Just set the

saturation value when you can not get the correct excitation curve in

automatic mode.

Show excitation curve data in brief mode

If Show excitation curve data in brief mode has been selected, the

excitation data table items will be not more than 30 points, 15 points

before knee point and 15 points after knee point. All those points are

sampled from excitation curve measured in the same step.
If this item is not selected, all the excitation curve data will be showed in excitation curve data table.

Transformer secondary current guess threshold value

This parameter is valid in nameplate information guess. Analyzer

guesses the rated secondary current of CT according to this parameter.
If the winding resistance measured in CT secondary is lower than this

value, Analyzer will set the rated secondary current of CT to 5A.

Otherwise, the rated secondary current of CT is 1A.

1A CT core type guess threshold value

This parameter is valid in nameplate information guess. Analyzer

guesses the core type of 1A CT according to this parameter.
If the knee point voltage of 1A transformer is lower than this value,

Analyzer will set the core type of CT to measurement. Otherwise, the

core type of CT is protection.

5A CT core type guess threshold value

This parameter is valid in nameplate information guess. Analyzer

guesses the core type of 5A CT according to this parameter.
If the knee point voltage of 5A transformer is lower than this value,

Analyzer will set the core type of CT to measurement. Otherwise, the

core type of CT is protection.

Excitation data search mode

If search current from voltage is selected, Analyzer will find the right

current value in excitation curve by the voltage value inputted.
If search voltage from current is selected, Analyzer will find the right

voltage value in excitation curve by the current value inputted.


Safety regulations for CT/PT Analyzer application


1.All technical index should keep in work condition before testing with Analyzer.

2.Please follow associated international standards in a special application.

3.Forbid high voltage or high current connected to CT/PT Analyzer directly.

4.All tests need to follow procedure in user manual.

5.It is forbid to open the box of CT/PT Analyzer. Otherwise, the quality assurance will be invalid.

6.It is forbid to update or extend the tester without manufacturer authorization.

7.Please use the original accessories for Analyzer.

8.It is forbid to cut off test connection before LED indicator light is OFF.

9.Please connect Analyzer to ground with grounding cable in no laboratory application.

10.Please confirm that one terminal of sample CT primary connected to ground.

11.Do not run Analyzer in extreme moist condition.

12.Please confirm that all terminals connected to Analyzer have no voltage. All voltage outputs are from CT/PT Analyzer.

13. Please confirm that voltage had been injected to CT secondary winding in CT test. Otherwise, CT/PT Analyzer will be damaged possibly.

14.Please confirm that voltage had been injected to PT primary winding in PT ratio test. Otherwise, CT/PT Analyzer will be damaged possibly.

15.The ratio error and phase angle error test is valid for electromagnetic voltage transformer only. It can not applied in CVT test.

11

The appearance of CT/PT Analyzer is as figure bellow

1

  Wuhan Goldhome Hi pot Electrical Co.,ltd(short for Goldhome Hi pot) was established in 2008, its predecessor was state-owned third industry enterprises, one of the earliest enterprises specially in develop, design and manufacture high voltage testing equipment in China.In 2016, merged with Wuhan Sang Electric Co., Ltd. , we realize advantageous compartmentalize and resources reorganization.Now it has become a high-tech enterprise integrating R&D, production, marketing installation and commissioning.1.our-historyOur FactoryGoldhome Hi pot is located in Huading Mould Industrial Park, Economic and Technical Development Zone, Wuhan City, Hubei Province, China, working area more than 4000 square meters.As a high-tech enterprise, we are supported by natural advantages from various research universities in Wuhan city. Goldhome Hi pot works closely with professors from State Grid Power Science Research Institute, Electrical Engineering Colleges of Wuhan University and other scientific research institutions, constantly improving technology and updating products . Now Goldhome Hi pot has more than 20 patented technologies, and many software Copyrights!2.our factory-1product and product applicationOur ProductOur advantage products included AC Resonant Test System, PD Free Test System, AC/DC Hi pot Tester, Primary Current Injection, VLF Hi pot Tester, transformer tester,impulse generator,Transformer oil tester,HV Switch gear Tester ,Insulation Tester,ground Resistance Tester,cable fault locator,relay test set,CT PT analyse,arr ester tester and sf6 gas analyzer,etc.Product ApplicationAll the performance indexes of above testing equipment can reach the leading level in China, widely used in power supply bureau, power plant, power construction, railway, petroleum, chemical industry, metallurgy, coal and other industries.In recent years,our factory continues to expand overseas markets, some competitive products are already exported to American and European countries, Africa, Middle East, etc , and well praised by customers.product applicationOur CertificateAll product process is strictly in accordance with international standards and power industry regulations. And the products are through the national, provincial power authorities testing, as well as CE certification! At present,0ur company has received ISO9001:2015 quality management system certification, ISO14001:2018 occupational health and safety management system certification, and ISO14001:2015 environmental management system certification,and also had got SGS certification.We has more than 20 patented technologies,such as The utility model patent of a frequency conversion series resonance test device,The utility model patent of Lightning impulse voltage testing equipment,The utility model patent of DC high voltage generator,The utility model patent of microcomputer relay protection tester,The utility model patent of High voltage switching characteristic tester., etc.4.certificateoverseas market & our serviceOverseas MarketOur products are sold to Europe, Asia, Africa, North and South America and Oceania, Middle East, etc.and are well received by customers.We had won the bids for the purchase of high-voltage no-partial discharge test equipment from the Polish state-owned insulator production plant, the Myanmar National Grid cable fault tester purchase project, and the high-voltage test equipment purchase project of a Russian power installation and test engineering company.We also sell to end customers, and a single device can also be sold. For example, there are power maintenance and installation companies in Indonesia, South Africa, Denmark, and South Korea, and universities and research institutions purchase and use our test equipment.At the same time, our sales targets also include agencies. At present, we already have cooperated with agents in Singapore, Israel, Mauritius , etc.We insist on providing customers with first-class products and first-class services with reliable product quality and perfect service team.5market-1Our service1.Strict factory testAll products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.2.Providing technical materialsDuring the product acceptance, we provide the related manual sheets, packing list,qualified certificate labels, factory test reports and other technical documents.3. Support technical guidanceWe also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!After-sale service1.First-use responsibility systemAfter the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part2.One year warrantyAll products warranty is 1year, life-time maintenance .During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !3.TroubleshootingIf the troubleshooting is not difficult, and client can handle with it by themselves, we can offer the call-on line guide within 1 hour!If the troubleshooting is difficult to handle with for client, we can promise that the best solution can be provided within 24 hours!
Similar Product Recommend