Illustrate:CX-FS-FB12 baffle flow switch is used for gas and liquid . Suitable for industrial automation / mechanical equipment/compressed air industry /refrigeration and air conditioning .
CX-FS-FB12 Baffle flow switch
Application
CX-FS-FB12 series Baffle flow switch is mechanical type flow switch . Built-in baffle supported by reed . When the flow rate reaching the set value , the mechanical structure trigger micro-trigger switch .
Feather
1, With extremely small pressure loss 2, Good repeatability 3,With high anti-stain ability 4,Accurate switch setup through knob 5,The mechanical part isolate with electric part totally . 6.With online installation
Technical Parameters| Set range | 1…150cm/s( water),3…300cm/s(oil),20…2000cm/s(air) |
| Output | PNP, NPN, Relay ,4-20mA, NO+NC (SPDT) |
| Power supply | 24V±20%DC |
| Switching Current | Max.400mA(PNP or NPN type ), Max.4A( Relay type ) |
| Unload current | Max.80mA |
| Flow indicator | LED (6) |
| Set type | potentiometer set |
| Proof Pressure range | 100bar |
| Temperature gradient | 4℃/s |
| Response time | 1--13s,standard is 2s |
| Initialization time | 8s |
| Electrical protection | reversed-phase ,short circuit ,overload protection |
| Protection class | IP67 |
| Medium temperature | 20--80℃ |
| Environment temperature | -20--80℃ |
| Storage temperature | -20--100℃ |
| Connection | M12 connector /2m cable (option) |
| Material | Probe is stainless steel . Housing is PBT |
Dimension
Installation
Note : Installation location will effect the switch value .
Wiring
Medium
Parameter 1 , Suitable for the pipe <=40mmDiameter DN | Interface screw D | Type | Pressure Bar | Adjustable range L/min(water) | Delay L/min(water) | Weight kg |
| 20/ | G3/4"Taper thread | FB12-020GK/A | 16 | 4.2…18 | 2 | 0.85 |
| 20 | G3/4" Taper thread | FB12-020GK/B | 16 | 8.3…37 | 3 |
| 25 | G1" Taper thread | FB12-025GK/A | 16 | 5.2…23 | 2 |
| 25 | G1" Taper thread | FB12-025GK/B | 16 | 11…48 | 4 |
| 32 | G1 1/4" Taper thread | FB12-032GK/A | 16 | 8.1…39 | 3 |
| 32 | G1 1/4" Taper thread | FB12-032GK/B | 16 | 19…90 | 6 |
| 40 | G1 1/2" Taper thread | FB12-040GK/A | 16 | 15…69 | 5 |
| 40 | G1 1/2" Taper thread | FB12-040GK/B | 16 | 25…111 | 7 |
Note : It vertically install on the horizontal pipe to get the above parameter . The measured medium is water at 20 Celsius degree .
Cixi flowmeter Co., Ltd. was established in 1986 and we have especially set up Shanghai Cixi Instrument Co. Ltd in order tohandle the deals of Export and obtained the License of Export and Import in 2008. Since 1986, Cixi flowmeter Co. Ltd has beendedicating itself to research and manufacture of various kinds of flowmeters and level meters. With sophisticated experience intechnology and management, we has made a name for itself as an excellent manufacturer of various kinds of flowmeters andlevel meters. Thanks to outstanding performance of products, CIXI Flowmeters are being applied in more and more fields wherethere's liquid to measure. CIXI Flowmeters have found users in many countries besides China, such as Malaysia, India, Thailand,Vietnam, South Africa and so on. Increasing number of users are finding that CIXI Flowmeter are kind of product with superperformance and reasonable price. our target is to serve our customers eficiently and innovatively in order to save their moneyand time. Any requirements from you will be responded in 24 hours.