Membership
Help
Cixi flowmeter Co., Ltd.
Cixi flowmeter Co., Ltd.
CX-VFM Vortex Flow Meter
| Nominal diameter(mm) | 25,40,50,65,80,100,125,150,200, 250,300,(300~1000 Insert type) |
| Nominal pressure (MPa) | DN25-DN200 4.0(>4.0 Supply agreement), DN250-DN300 1.6(>1.6 Supply agreement) |
| Medium temperature(℃) | Piezoelectric type:-40~260,-40~320;Capacitance type : -40~300, -40~400,-40~450(Supply agreement) |
| Body material | 1Cr18Ni9Ti,(Other materials supply agreement) |
| Allowable vibration acceleration | Piezoelectric type:0.2g Capacitance type:1.0~2.0g |
| Accuracy | ±1%R,±1.5%R,±1FS;Insert type:±2.5%R,±2.5%FS |
| Range of | 1:6~1:30 |
| Power supply voltage | Sensor:+12V DC,+24V DC;Transmitter: +12V DC ,+24V DC;Battery type:3.6V Battery |
| Output signal | Square wave pulse ( not including the battery power supply type ): high level or low level5V,1V; current: 4~ 20mA |
| Pressure loss coefficient | In line with the JB / T9249standard Cd = 2.4 |
| Explosion proof marks | Intrinsic safety type: Exd IA CT2-T5 flameproof type: Exd CT2-T5 |
| Protection grade | The ordinary IP65 diving type IP68 |
| Environmental conditions | Temperature - 20~ 55,5% ~ 90% of relative humidity, atmospheric pressure is 86 ~ 106kPa |
| Applicable medium | Gas, liquid, steam |
| Transmission distance | Three wire system pulse output type: < 300m, two line standard current output type (4 ~ 20mA ): load resistance less than 750ohm |
| Meter diameter (mm) | Liquid | Gas | ||
| Measuring range (m3/h) | Output frequency range(Hz) | Measuring range (m3/h) | Output frequency range(Hz) | |
| 25 | 1.2~16 | 25~336 | 8.8~55 | 190~1140 |
| 40 | 2~40 | 10~200 | 27~205 | 140~1040 |
| 50 | 3~60 | 8~160 | 35~380 | 94~1020 |
| 80 | 6.5~130 | 4.1~82 | 86~1100 | 55~690 |
| 100 | 15~220 | 4.7~69 | 133~1700 | 42~536 |
| 150 | 30~450 | 2.8~43 | 347~4000 | 33~380 |
| 200 | 45~800 | 2~31 | 560~8000 | 22~315 |
| 250 | 65~1250 | 1.5~25 | 890~11000 | 18~221 |
| 300 | 95~2000 | 1.2~24 | 1360~18000 | 16~213 |
| (300) | 100~1500 | 5.5~87 | 1560~15600 | 85~880 |
| (400) | 180~3000 | 5.6~87 | 2750~27000 | 85~880 |
| (500) | 300~4500 | 5.6~88 | 4300~43000 | 85~880 |
| (600) | 450~6500 | 5.7~89 | 6100~61000 | 85~880 |
| (800) | 750~10000 | 5.7~88 | 11000~110000 | 85~880 |
| (1000) | 1200~1700 | 5.8~88 | 17000~170000 | 85~880 |
| >(1000) | Agreement | Agreement | ||
| Spectrum | Explain | ||||||||||
| LU | Vortex flow meter | ||||||||||
| G | Sensor | ||||||||||
| Detection mode | B | Piezoelectric sensor | |||||||||
| E | Capacitance type sensor | ||||||||||
| Connection mode | 1 | Only the full pipe type | Flange connection | ||||||||
| 2 | Only the full pipe type | The flange clamp type | |||||||||
| 3 | Only to insert type | Simple insertion type | |||||||||
| 4 | Only to insert type | Insertion type ball valve | |||||||||
| Measurement of medium | 2 | Liquid | |||||||||
| 3 | Gas | ||||||||||
| 4 | Steam | ||||||||||
| Nominal diameter | 02 … 30 | | DN25 … unit:mm DN300 | ||||||||
| The use of the environment | P | Ordinary type | |||||||||
| B | Explosion proof type | ||||||||||
| Output signal | 1 | Pulse output | |||||||||
| 2 | 4 ~ 20mA output current, liquid crystal display | ||||||||||
| 3 | RS-485 communication | ||||||||||
| 4 | Battery powered, with temperature, pressure compensation | ||||||||||
| 5 | The temperature and pressure compensation for one, 4 ~ 20mA current output type | ||||||||||
| 6 | The temperature and pressure compensation integrated, battery power supply type | ||||||||||
| Type description | For example: LUGE2405-P2 full pipe type capacitive vortex flow meter, a flange clamp connection, medium for steam Instrument path for DN50, general 4~ 20mA output current signal | ||||||||||
| Nominal diameter DN mm | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 |
| Tag number | 02 | 03 | 04 | 05 | 06 | 08 | 10 | 12 | 15 | 20 | 25 |
| Nominal diameter DN mm | 300 | 350 | 400 | 450 | 500 | 600 | 700 | 800 | 1000 | 1200 | 1500 |
| Tag number | 30 | 35 | 40 | 45 | 50 | 60 | 70 | 80 | A0 | A2 | A5 |