Welcome Customer !

Membership

XwbooElectrical & ElectronicsLow Voltage ApplianceMiniature Circuit BreakerDAM1 400 MCCB Moulded Case Circuit Breaker
  • $item.Title
  • $item.Title

DAM1 400 MCCB Moulded Case Circuit Breaker

Shanghai DaDa Electric Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Miniature Circuit Breaker
Place of Origin
ShangHai,
The DAM1 series circuit breakers are intended for conducting current in normal mode and switching it off at short circuits, overload, inadmissible bucking as well as operational actuation and tripping of electric circuit parts. They are designed for use in electric units having the operative voltage limited to 400V per rated current from 12,5 to 1600A.They correspond to the requirements of EN 60947-1, EN 60947-2 .

Thermal-Magnetic Circuit Breakers
Thermal protection function:(For protection under over load conditions)
Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing through the breaker. Because, increase of current means increase of heat. In this way, over current protection function of the breaker is fulfilled by bimetal at load currents higher than the rated current

Magnetic protection function (For protection under short circuit conditions)
Another function of the breaker is to protect the connected circuit against short circuits. Short circuit may occur as a result of contact of phases with each other or contact of phase-ground. Since a very high current shall pass through the cables in case of short circuit, system energy should be broken in a shorter time due to thermal protection. Breaker should perform instant opening to protect load it is connected to. The part fulfilling this function is a mechanical opening mechanism that operates with magnetization caused by the magnetic
area formed by the short circuit current

Advantages

• Easy independent installation of auxiliary devices:
Alarm contact;
Auxiliary contact;
Under voltage release;
Shunt release;
Handle operating mechanism;
Electrical operating mechanism;
Plug-in device;
Draw-out device;.
• Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting onto an installation panel.
• With the help of special clamp 125 and 160 units can be installed onto a DIN-rail.
• Weight and dimensions of these circuit breakers are by 10-20% less than that suggested by other home manufacturers. This fact provides for mounting smaller boxes and panels. Besides, small dimensions make it possible to change old circuit breakers to DAM1.

Application

Moulded case circuit breakers are low-voltage circuit breakers. They meet the installation needs of small users all the way to large industrial substations and power distribution systems. They are commonly applied in steel mills, oil platforms, hospitals, railway systems, airports, computing centers, office buildings, convention centers, theaters, skyscrapers, and other large scale structures.

Electrical parameters of DAM1 MCCB molded case circuit breaker
• Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
• Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)
ON/I Position:It indicates that contacts of the breaker are closed. In this position, the breaker lever is in the top position
TRIP Position:It indicates that the breaker is opened due to any failure (over load or short circuit). In this case, breaker lever is in the middle position between ON and OFF positions. In order to take the breaker, which is in trip position, to ON position; push the breaker lever downwards as shown by the OFF sign
Breaker shall be set with “click” sound.After that, pull the lever as shown by ON sign to close the breaker
OFF/0 Position:It indicates that contacts of the breaker are open. In this way, the breaker lever is in the bottom position.

Physical parameters of DAM1-400 MCCB molded case circuit breaker

Category (EN 60947-2/IEC 60947-2)

Endurance

Model

Pole

Dielectric Propery (V)

lonization distance (mm)

Total Cycles

Electrical Life

Mechanical Life

Main circuit

Auxiliary circuit

DAM1-160

1P

2500

≤30/0

20000

3000

17000

A/0

AC-15

DAM1-200

2P

2500

≤30/0

15000

2500

12500

A/0

AC-15

DAM1-125

3P / 4P

2500

≤30/0

8000

1000

7000

A/0

AC-15

DAM1-160

3P / 4P

3000

≤30/0

8000

1000

7000

A/0

AC-15

DAM1-250

3P / 4P

3000

≤30/0※

8000

1000

7000

A/B

AC-15

DAM1-630(400)

3P / 4P

3000

≤60/0※

5000

1000

4000

A/B

AC-15

DAM1-800

3P / 4P

3000

≤80/0※

5000

1000

4000

A/B

AC-15

DAM1-1600

3P / 4P

3000

≤80/0※

3000

500

2500

A/B

AC-15

DAM1_01 DAM1_02 DAM1_03 DAM1_04 DAM1_05 DAM1_06 DAM1_07 DAM1_08 DAM1_09 DAM1_10 DAM1_11 DAM1_12 DAM1_13 DAM1_14 DAM1_15 DAM1_16

  SHANGHAI DADA ELECTRIC CO.,LTD was established in 2004, is acknowledged as one of the most respected nationwide manufacturers low voltage CIRCUIT BREAKER in China. A wide range products cover miniature circuit breakers(MCB), residual current circuit breakers(RCCB),Residual Current Circuit Breakers With Overcurrent Protection (RCBO), moulded case circuit breakers(MCCB),AC Contactor, thermal overload relay,Motor Protection Circuit Breaker,etc.Why choose CDADA?PRODUCTION WORKSHOPThe Group, comprising 3 factories, owns a production area of 52,400m2 and employs more than 500 staff.WorkshopWe utilize a punching workshop, injection molding workshop, hydraulic workshop, spot welding and riveting workshop, assembly workshop, and quality inspection workshop that meets all of our quality management necessities.StaffThe production center is staffed by 400 employees including 32 technical staff members, and 30 senior management personnel. We have many industry experts in low-voltage electrical appliances.EquipmentThanks to this high efficiency facility, we have surpassed an annual output of 800,000 MCCB and 5,000,000 MCB units.Our circuit breaker products are specially designed to meet the wide range of installation needs of small users all the way to industrial transformer substations and power distribution stations. You will find our products installed in steel mills, oil platforms, hospitals, railway stations, airports, computing centers, office buildings, convention centers, theaters, skyscrapers, and any other building with electricity demands.Dada remains dedicated to the development and manufacturing of circuit breakers. We have successfully expanded our global business to more than 20 countries and regions across Europe, America, Middle East, Africa and Southeast Asia. For many years, we have participated in bidding on project for the Chinese national grid, building our company brand and expanding our capabilities and reach. We continue reaching for this goal by adhering to the corporate philosophy of “Think more for the customers and do better for the customer”. Ultimately, we aim to increase the intelligentization of electricity management and we are committed to becoming a world-class leader in quality electrical products. Dada looks to transform the Chinese electrical system, but also the world's.Our Mission? CDADA is devoted to providing high quality products by supplying products from superior manufacturers and providing first-rate customer service.? We are committed to providing the global companies with superior quality circuit breaker products to help compete in today’s marketplace.Our Team? Our R&D team is focused on developing innovative circuit breaker technology to ensure our customers have access to the highest quality products.? Our staff has more than 30 years of experience provides personalized customer service every step of the way.