Membership
Help
Ningbo Water Meter (Group) Co.,Ltd
Ningbo Water Meter (Group) Co.,Ltd
ULTRASONIC DOMESTIC WATER METER
NWM UL-DW
NWM UL-DW is the static ultrasonic water meters covered from Dn15 to Dn40 for domestic and commercial application, its robust design ensures reliable and long lasting precision and support full smart IoT solutions.

1 Non-moving parts
Non-moving parts permitting the most reliable and longer term life; lowest pressure loss;
2 High accuracy
High accuracy, unaffected by sand, suspended solids or air pockets;
3 Reverse flow detect
It can detect both forward and reverse flow
4 Long battery life
10 years battery life, longer endurance
5 Communication
AMR ready for wire or wireless communication
6 IP 68
IP 68 environment protection class

| Size | Dn15 | Dn20 | Dn25 | Dn32 | Dn40 |
| L | 130/165 | 130/154/190 | 225/260 | 225/260 | 245/300 |
| L1 | 244/259 | 234/258/294 | 345/380 | 349/380 | 331/386 |
| D | G3/4B | G1B | G1-1/4B | G1-1/2B | G2B |
| d | R1/2 | R3/4 | R1 | R1-1/4 | R1-1/2 |
| H | 123 | 123 | 152 | 152 | 152 |
L1: the length of the water meter with connection
| DN | mm | 15 | 20 | 25 | 32 | 40 |
| R | Q3/Q1 | 250 | 250 | 250 | 250 | 250 |
| Q4 | m3/h | 3.125 | 5 | 7.875 | 12.5 | 20 |
| Q3 | m3/h | 2.5 | 4 | 6.3 | 10 | 16 |
| Q2 | l/h | 16 | 25 | 40 | 64 | 102 |
| Q1 | l/h | 10 | 16 | 25 | 40 | 64 |
| Starting flow rate | l/h | <4 | <4 | <4 | <8 | <11 |
| Max. reading | m3 | 99 999.999 | ||||
| Min. reading | liter | 0.1 | ||||
| Min. reading (calibration) | liter | 0.0001 | ||||
(For different Q3 and R, please contact with NWM).
| Max. pressure | MAP16 | Installation position | Any position |
| Max. temperature | T30 / T50 | Climate and EMC Class | (B/O)(E1,M1) |
| Display Interface | Instantaneous ow, Accumulate ow, Wireless signal Working status, Reverse ow detect… | ||
| Communication port | Optical (infrared ray), M-Bus, Pulse Raido Frequency, LoRa, NB-IoT... | ||


Suggest to install the UL-DW water meter at U5 D3 (Straight pipe before the water meter at 5D, after the water meter at 3D); Water flow should be in the same direction with the arrow on water meter main case; if installed horizontally (or vertically), water meter surface should face right upwards (or right ahead), and it cannot have any deection from water meter outlet axis; The installation location should be protected from sunlight, freezing, pollution and water drown for easy removing and cannot be installed near the inlet and outlet of the pump; Flush the pipe work thoroughly to clear all impurities before installing the water meter; The water meter and pipeline should be connected by pipefitting, sealing gaskets and connecting nuts (the connections).
From Q1 inclusive up to but excluding Q2 is ± 2% for T30 (From Q1 inclusive up to but excluding Q2 is ± 3% for T50); From Q2 inclusive up to and including Q4 is ± 5%;