ELR-3C Ground Leakage Protection Relay (Zero-sequence Current Detection)

Naidian Group Co., LTD.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Regulated Power Supply
Place of Origin
ZheJiang, WenZhou
ELR-3C Ground Leakage Protection Relay (Zero-sequence Current Detection)

Function

1.Modular exterior Design (3*17.5mm appearance width)

2.Intensive electronic circuit design, strong anti-jamming performance Intensive electronic circuit design, strong anti-jamming performance

3.Accurate grounding leakage fault protection function, suitable for power system and motor grounding fault protection Accurate grounding leakage fault protection, suitable for power system and motor grounding fault protection 

4.Zero sequence current transformer detects ground fault

5.The leakage current can be set in a wide range,Min Set is 25MA and Max is 25A.

6.Action delay time set a wide range, the minimum can set 0.02 seconds, the maximum can set 5 seconds 

7.The action current and the action delay can be separately adjustable

8.Manual and automatic reset can be selected by dial code switch to select 

9.LED lamp indicating power input and fault state

10.TEST test key and RESET reset button

11.A product collection of multiple supply voltage inputs: 380-415VAC; 220-240VAC; 110-127VAC/DC

12.35mm Guide rail installation

 

Application

1.Distribution line grounding fault protection

2.General grounding fault protection load

3.Direct grounding protection

4.High resistance grounding fault protection grounding

 

1.

Current release setting potentiometer

2.

Trip time setting potentiometer

3.

Microswitch for programming

In position 1 automatic reset, 0 manual reset Multiplication constant selection

Action tripping delay time, position 1 K=10 times; Position 0 K=1 times;

C.D selects tripping current times constant:position is 0 K=0.1 times C at position 1D at position 0 K=1 times; C,D at position 1 K=10 times

4.

Test button

5.

Manual reset button

6.

Green power supply normal indicator light

7.

Red TRP Fault indicator for Relay tripping

Hookup

Naidian Group Co., LTD.Naidian always keep the aim about "brand manufacturing intentions, customer safety assured", in line with the high sense of responsibility for the society and users, and adhere to the development strategy of "doing fine main business, extension development", the company will do its best to attract famous enterprises with first-class brand, quality and service.Since its establishment in 1989, the company has always focused on the field of intelligent power system, adhere to the market demand-oriented, technological innovation as the power source of enterprise development,has a qualified research and development experienced expert team, familiar with the actual operation of China's power grid, technology and process innovation, adhere to the industry leading position.