Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
Explosion Proof Electromagnetic Flow Meter
The Explosion Proof Electromagnetic Flow Meter is special processed on the electric part, the safety grade meet the international standard. The shell of the electrical part had passed the test for temperature and the inner heat resisting, ensure that there is no possibility to cause the explosion by the circuit spark inside the flow meter. The Electric terminal is all made by stainless steel which isolate the circuit part inside the shell. The explosion proof electromagnetic flow meter now is widely used in the working ambient have explosion proof request such as the chemical factory, oil field, vessel etc.


| Measure Medium | Water,Sewage,Acid,Alkali,Slurry,Milk | |||
| Nominal diameter | 15-500mm | |||
| Degree of accuracy | ±0.5%R | |||
| Medium conductivity | ≥5uS/cm,Actual conductivity≥30uS/cm | |||
| Nominal pressure | 1.0MPa | 1.6MPa | 2.5MPa | 4.0MPa |
| DN15-DN500 | DN15-DN500 | DN15-DN500 | DN15-DN50 | |
| Highest medium temperature | Compact type | +80℃ | ||
| Remote type | CR chloroprene rubber liner (CR) | +80℃ | ||
| Polytetrafluoroethylene lining(F4) | +120℃ | |||
| Politef lining(F46) | +120℃ | |||
| Teflon(PFA) | +180℃ | |||
| Fluorosilicone rubber(FVMQ) | +250℃ | |||
| Output signal | 4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max) | |||
| Supply voltage | 110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10% | |||
| Communication | RS-485,Support standard Modbus-RTU protocol;GPRS | |||
| Electrode material | Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum | |||
| Level of protection | Remote type | IP68,IP65 | ||
| Compact type | IP65 | |||
Explosion Proof Electromagnetic Flow Meter Product advantage
High Precision
PHILPS military level CPU,
EMC standard anti-jamming.
Basic function
Low frequency square wave excitation, excitation frequency: 1 ≤ 10 power frequency, 1 ≤ 16 power frequency, 1 ≤ 25 power frequency;
The excitation current can be selected as 125mA, 187.5mAand 250mA. the excitation current can be selected as 125mA, 187.5mA and 250mA, respectively.
Network function: MODBUS,HART (optional);
English display, (can be customized in other languages);
There are three accumulators in the interior, which can be recorded separately: positive total, reverse total and total difference.




Explosion Proof Electromagnetic Flow Meter