Welcome Customer !

Membership

XwbooGeneral Machinery Valve Other ValvesFan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve
  • $item.Title
  • $item.Title

Fan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve

Nanjing Saiko Controls Co., Ltd.

Model
Nature of the Manufacturer
Other
Product Category
Other Valves
Place of Origin
,
Fan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve

Fan Coil Electric Actuated Spring Return Actuator Motorized Valve 1.6 MPa Brass Ball Control Valve
 

The SK series brass motorised valves are primarily designed to control the flow of water or steam in response to the demand of a controller in zone and fan coil applications.

The valve is driven by hysteresis synchronous motor with spring return. The valve is normal-closed. When thethermostat is working, it will provide an opening signal, and the motorized valve will be turned on to open. Thenthe chilled/hot water will enter into the coil and supply the cold/hot to the room. When the room temperature risesup to the set point, the thermostat will make the valve power off. At the same time the valve will be closed byreturn spring and the water to the coil will be shut off. The room temperature will be kept in the setting range allthe time through the opening and closing of the valve.

Fan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve

 

Technic parameters:

Operating voltage220~240VAC 50/60Hz
Full stroke time 'on'approx.10s
Full stroke time 'offapprox.5s
Close-off pressure0.2Mpa
Applied mediaChilled/Hot water


Character of structure
1.Inlay contact switch, the motor is power off after the valve completes open and close, so it has long service life and power saving, but is also safe.
2.The valve body is separated with driver, could be disassembled rapidly.
3.The valve body structure is unique, is allowed of big pressure difference.
4.The driver has manual controller is available for system debugging and maintenance, the manual opening is about 70% (push down the white driving arm to the bottom, and then push inside, when the power is recovered, the valve and driver will return to automatic position)
5.B type driver has inlay relay, one-line control and three-speed switch, realize multi valves parallel, and match with various temperature control switches. (special for four-pipe)
6.Select ordinary driver, one temperature controller matches only one electric vale, or any results caused will be nothing with manufacturer.

Fan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve



Points for installation
1.Please read this instruction carefully before installation, ask professional to perform installation and connect according to wiring diagram.
2.The electric valve should be installed to the place with certain distance from around articles, but also could be reached by maintenance person. No electric equipments are allowed to install under the valve body, as to avoid leakage and danger. The driver shall be above the valve body horizontally.
3.Clear up the sundries in the pipe before installation, install 50 mu (or thinner) filter in the front end of electric valve.

 

Pipe Connecting Instruction

  Motorized control valve should be mounted on cold/hotwater inlet or outlet pipe of fan coil unit for opening orclosing cold /hot water. The actuator is controlled by theroom thermostat.

  2-way valve(see Fig 1) is installed on cold/hot return water (CHR) pipe , when de-energized, the rubber insidenormally closed at port "B" , stop water flow. when energized, the rubber moved from port "B" to the centerof port "B" & "A" and cold/hot water flow through 2-wayvalve to return water pipe.

Fan Coil Spring Return Actuator Motorized Valve / 1.6 MPa Brass Ball Control Valve

 

​

  When the actuator is de-energized, spring returnmechanism drives valve to normally closed position,port "B" is closed . Cold/hot water inlet from port "AB"(bottom)by-pass to port "A" to return water pipe ,

when energized , rubber is moved from port "B" to port"A" and closed. Cold/hot water inlet from port "AB"through port "B" to fan coil unit then outlet to returnwater pipe.

 

Caution:

  2 & 3 way valve should not be installed in wrong flow direction to avoid vibration and noise; By-pass valveand Exp Tank is needed for water flow fluently.
 
Packing and delivery:
  • We will arrange the delivery once the payment pass risk monitoring. In order to protect both buyers and sellers, we need 8-24 hours to verify the payment.
  • The order will be sent out within 10 working days (excluding weekends and holidays) as soon as your payment is cleared .
  • 1PC/Inner Box, 20PCS/Carton

 

Service:

1.OEM and ODM are all welcome.
2.1 year warranty.
3.Answer your questions online 12h(8:00 a.m.~8:00 p.m.). 

 

12h online chat

Welcome to your inquiry!

We started producing electric in-floor heating in Jiangsu,China almost eight years ago in 2011 and have been growing steadily ever since. In 2015 we started selling our own specially-designed lines of in-floor heating products and two years later once we were confident had a winning product line we started offering them on-line to customers like you all across North Europe. During the summer of last year our sales had grown so much that we moved distribution and fulfillment from Lishui Distrct,Jiangsu to Jiangning Distrct, Jiangsu where we now have more space and offer quicker freight to many parts of the country more easily and at a lower cost than before. I invite you to check out our competitive pricing and to send us a request or call me personally if there is anything we can do to help you get started.
Similar Product Recommend