The Fatigue Rated Load Cells are similar to the Universal Load Cell models and are designed for fatigue measurement/control applications in both tension, compression and/or tension/compression directions. The load cells possess very low deflection, high natural frequencies, and a one billion cycles fatigue rating.
Dimensions:

PARAMETER | VALUE | UNIT |
Standard capacities (Emax) | 125 | KN |
Rated output-R.O. | 2.0 | mV/V |
Zero balance | 1 | ±% of rated output |
Non linearity | 0.1 | ±% of rated output |
Hysteresis | 0.05 | ±% of rated output |
Non-repeatability | 0.05 | ±% of rated output |
Creep error (30 minutes) | 0.05 | ±% of rated output |
Zero return (30 minutes) | 0.05 | ±% of rated output |
Temperature effect on min. dead load output | 0.0026 | ±% of rated output/℃ |
Temperature effect on sensitivity | 0.0015 | ±% of rated output/℃ |
Compensated temperature range | -10 to +40 | ℃ |
Operating temperature range | -20 to +60 | ℃ |
Safe overload | 150 | % of R.C |
Ultimate overload | 200 | % of R.C |
Excitation, recommended | 10 | Vdc |
Excitation, maximum | 15 | Vdc |
Input resistance | 720±20 | Ohms |
Output resistance | 700±3 | Ohms |
Insulation resistance | 5000 | Mega-Ohms |
Material | Alloy steel |
|
Protection class | IP67 |
|