Summary
XBC series diesel engine fire fighting pump is required to meet the standard GB6245-2006 and international fire pump standard NFPA20, Which designed by YONJOU PUMP. XBC fire pump is a fixed fire fighting device.
Mainly be applied for water and foam extinguishing system in petrochemical industry, natural gas, power station, cotton and linen textile industrial, warehouse, airport, wharf, high-rise buildings, and etc. And also available for ship, tanker, fire fighting naval vessels and etc. XBC fire pump can be equipped with Chinese brand good quality engine or import engine either.
YONJOU fire fighting pump can provide quick start, reliable water supply, suitable power supply, stable running, standardization, individualization, optimization, and wide range in pressure rate and flow rate. YONJOU brand XBC NFPA20 standard fire frighting pump is a dependable fire device.
Ensure the pump can continue on duty, fully pay emergency functions and long-life time, the proper maintenance is required.
To insure the operator fully understand the structure of the pump, operation and maintenance, right installation, YONJOU redact this manual for reference.
Specification data:
| Model | Diameter | Capacity | Pressure | Engine Power | Speed Range |
End Suction Fire fighting pump | 2-8 inch | 160-1760 GPM | 0.5-12.5 bar | 0.22-110kW | 1500RPM 1800RPM 2200RPM |
Multistage Fire fighting pump | 1.5-12 inch | 16.5~3740 GPM | 1.9~81.6 bar | 3-1600 kW | |
Split Case Fire fighting pump | 3-18 inch | 64~11000 GPM | 0.61~20 bar | 2.2-1800 kW | |
Submerged Fire fighting pump | 6-40 inch | 220-36960 GPM | 1.5-15 bar | 5.5-2000 kW |
Functional characteristics:
Wide range of pump | Fire pump can equip with end-suction pump,multistage pump,double-suction pump, rotor pump,wide range of flow and head. |
Auto operation | Once the fire pump received a fire signal,or power failure、lose phase of electric motor pump, or received a remote start signal,the pump set will auto start. |
Pump crank for 10 seconds,and if start failure it will restart again. | |
Indicator and alarm | Multiple start failure alarm,engine low lubrication alarm,engine high water temperature alarm,engine over speed alarm,low battery voltage alarm. battery charge failure alarm,low fuel level alarm. |
Multiple start mode | Manual,a variety of automatic start. |
Auto shut down | Pump auto shut down by the fire signal disappeared. |
Remote connect terminals | terminals as remote start, stop, pump set running, pump set comprehensive failure,etc. |
Direct connection | A coupling between engine and pump is required to directly connect, by this connection fewer failure and smaller vibration will have. |
Auto battery charging | When Auto mode on,during the standby time,a charger can supply a constant current, voltage to insure the battery have enough power. Once the battery fully charged, the charger will cut off the current automatically for in case the damage. |
Adjustable rated speed | Through adjusting engine speed,the pump flow and head can be adjusted to the required point. |
Double power supply | The starting current will be absorbed from either power supply alternately. If one set of power failure will change to anther one automatically.(Optional) |
Maintenance-free battery | No need to frequently refill the electrolyte.(Optional) |
Pre-heat | Make sure the engine can start normally in cold weather.(Optional) |
Timing start | Available to set timing start,to test pump could run regularly.(Optional) |
Why choose us:
1.The well respected manufacturer of fire fighting since 1989.
2.We have a Young and dynamic sales team.
3.Experienced professional technicians. Taking pride in our products.
4.Quality assurance! 99% tested before shipping to customers.
Customized according to customers’ demands.