Welcome Customer !

Membership

XwbooElectrical & ElectronicsWire & CableCable for Electrical EquipmentFlame retardant refractory cable NH-KVV ZR-NH-KVVP
  • $item.Title
  • $item.Title

Flame retardant refractory cable NH-KVV ZR-NH-KVVP

Anhui Hongye Instrumentation Cable Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Cable for Electrical Equipment
Place of Origin
AnHui, ChuZhou
Flame retardant refractory cable NH-KVV ZR-NH-KVVP
1.Use
This product is suitable for the control, monitoring, measurement and protection circuits of power frequency voltage 0.6 / 1kv and below equipment, fire alarm and fire fighting equipment, communication smoke extraction equipment and emergency aisle transportation, lighting and other emergency facilities. It is especially suitable for important places requiring high safety such as subways, underground shopping malls, high-rise buildings, intelligent communication buildings, and power stations.
 
2. Product model and name
Model
Name
WDZNKYJY
Copper core XLPE insulated polyolefin sheathed halogen-free low-smoke flame-retardant fire-resistant control cable
WDZNKYJYP2
Copper core structured, XLPE insulated, copper strip fired, shielded, polyolefin sheathed, halogen-free, low-smoke, flame-retardant and fire-resistant control cable
WDZNKYJY23
Copper core structured, XLPE insulated, steel strip armored, polyolefin sheathed, halogen-free, low-smoke, flame-retardant and fire-resistant control cable
3. Technical Parameters
Conductor nominal cross section mm2
DC resistance is not greater than 20℃ Ω/㎞
1.5
12.1
2.5
7.41
14
4.61
6
3.08
10
1.83
4. 规格
Type
 
Rated voltage
Conductor nominal cross sectionmm2
1.5
2.5
4
6
10
Number of cores
WDZN-KYJY
WDZN-KYJYP2
WDZN-KYJY23
0.6/1KV
2-61
2-14
2-10
2-14
7-61
4-61
4-14
Note: The recommended volume number series are 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, and 61 cores.
5. Product Features
With the characteristics of halogen-free low-smoke flame-retardant control cable.
Combustion in a flame environment of 750 ℃ + 50 ℃ and below, which can ensure the power on for 90min, and ensure that it can meet the requirements of emergency control.
Combustion performance
⑴Halogen gas release test, PH value ≥4.3, electrical conductivity ≤10μs / ram;
试验 Test on the amount of smoke emitted by the cable during burning, light transmittance ≥60%;
(3) Cable fire resistance test: Passed the fire resistance test specified in IEC60331 and GB / T19216;
⑷The cable flame retardant test passed the bundled Class A (Class B or Class C 0 combustion test specified in IEC60332 and GB / T18380)
Electrical performance
⑴Conductor DC resistance
⑵ Power frequency withstand voltage test 3000v / 5min without breakdown;
⑶ The insulation resistance constant at 90℃ is not less than 3.67MΩ.㎞.
Use characteristics
The long-term operating temperature of the cable conductor is 90℃.
The laying temperature of the cable is not lower than 0℃
Permissible bending radius:
The cable without armor should be no less than 8 times the outer diameter of the cable;
The armored cable should be no less than 16 times the outer diameter of the cable.
 

 

  At present, the main products produced and developed by the company are: bare copper stranded wires, computer cables, control cables, power cables, compensation cables, coaxial RF cables, high-temperature special cables, cross-linked cables, overhead cables, marine cables, fluoroplastic installation cables , Motor lead wires, instrument signal cables, pre-branched cables, various types of flame-retardant, fire-resistant, low-smoke halogen-free, intrinsically safe cables, rubber jackets, silicone rubber, polytetrafluoride and other high temperature special cables.
Similar Product Recommend