Membership
Help
Shanghai Xinhou Spraying & Purification Equipment Co., Limited
Shanghai Xinhou Spraying & Purification Equipment Co., Limited
Flood Jet Wide Angle Flat Fan Spray Nozzles produce a wide angle, deflected type flat fan spray pattern Thread size range from 1/8’’ to 2’’ with BSPT or NPT thread type Stable spray angle with uniform, parabolic distribution of liquid.
![]() Flood Jet Wide Angle Flat Fan Spray Nozzles | ![]() |
Parameter
Flow Code | Orifice Dia. (mm) | Flow rate (L/min) | Spray Angle | ||||||||||
|
| 1 ( us gal) = 3.785 L ; 1 ( uk gal) = 4.546 L |
| ||||||||||
|
| 0.2 bar | 0.3 bar | 0.5 bar | 0.7 bar | 1 bar | 1.5 bar | 2 bar | 3 bar | 4 bar | 0.5 bar | 1.5 bar | 4 bar |
0.25 | 0.41 |
|
|
|
| 0.11 | 0.14 | 0.16 | 0.2 | 0.23 |
| 83° | 117° |
0.5 | 0.61 |
|
|
|
| 0.23 | 0.28 | 0.32 | 0.39 | 0.46 |
| 89° | 122° |
0.75 | 0.71 |
|
|
| 0.29 | 0.34 | 0.42 | 0.48 | 0.59 | 0.68 |
| 106° | 125° |
1 | 0.84 |
|
|
| 0.38 | 0.46 | 0.56 | 0.64 | 0.79 | 0.91 |
| 109° | 128° |
1.5 | 1 |
|
| 0.48 | 0.57 | 0.68 | 0.84 | 0.97 | 1.2 | 1.4 | 73° | 108° | 125° |
2 | 1.2 |
|
| 0.64 | 0.76 | 0.91 | 1.1 | 1.3 | 1.6 | 1.8 | 83° | 113° | 129° |
2.5 | 1.3 |
| 0.62 | 0.81 | 0.95 | 1.1 | 1.4 | 1.6 | 2 | 2.3 | 98° | 122° | 133° |
3 | 1.4 |
| 0.75 | 0.97 | 1.1 | 1.4 | 1.7 | 1.9 | 2.4 | 2.7 | 86° | 112° | 126° |
4 | 1.7 |
| 1 | 1.3 | 1.5 | 1.8 | 2.2 | 2.6 | 3.2 | 3.6 | 97° | 123° | 132° |
5 | 1.9 | 1 | 1.2 | 1.6 | 1.9 | 2.3 | 2.8 | 3.2 | 3.9 | 4.6 | 114° | 128° | 142° |
7.5 | 2.3 | 1.5 | 1.9 | 2.4 | 2.9 | 3.4 | 4.2 | 4.8 | 5.9 | 6.8 | 101° | 119° | 134° |
10 | 2.6 | 2 | 2.5 | 3.2 | 3.8 | 4.6 | 5.6 | 6.4 | 7.9 | 9.1 | 115° | 133° | 145° |
12 | 2.9 | 2.4 | 3 | 3.9 | 4.6 | 5.5 | 6.7 | 7.7 | 9.5 | 10.9 | 128° | 139° | 153° |
15 | 3.3 | 3.1 | 3.7 | 4.8 | 5.7 | 6.8 | 8.4 | 9.7 | 11.8 | 13.7 | 98° | 113° | 123° |
18 | 3.6 | 3.7 | 4.5 | 5.8 | 6.9 | 8.2 | 10 | 11.6 | 14.2 | 16.4 | 106° | 120° | 131° |
20 | 3.8 | 4.1 | 5 | 6.4 | 7.6 | 9.1 | 11.2 | 12.9 | 15.8 | 18.2 | 110° | 122° | 133° |
22 | 4 | 4.5 | 5.5 | 7.1 | 8.4 | 10 | 12.3 | 14.2 | 17.4 | 20 | 113° | 125° | 136° |
24 | 4.1 | 4.9 | 6 | 7.7 | 9.2 | 10.9 | 13.4 | 15.5 | 18.9 | 22 | 115° | 131° | 144° |
27 | 4.4 | 5.5 | 6.7 | 8.7 | 10.3 | 12.3 | 15.1 | 17.4 | 21 | 25 | 119° | 135° | 148° |
30 | 4.6 | 6.1 | 7.5 | 9.7 | 11.4 | 13.7 | 16.7 | 19.3 | 24 | 27 | 100° | 110° | 121° |
35 | 5 | 7.1 | 8.7 | 11.3 | 13.3 | 16 | 19.5 | 23 | 28 | 32 | 105° | 118° | 128° |
40 | 5.3 | 8.2 | 10 | 12.9 | 15.3 | 18.2 | 22 | 26 | 32 | 36 | 111° | 126° | 136° |
45 | 5.6 | 9.2 | 11.2 | 14.5 | 17.2 | 21 | 25 | 29 | 36 | 41 | 115° | 130° | 140° |
50 | 6 | 10.2 | 12.5 | 16.1 | 19.1 | 23 | 28 | 32 | 39 | 46 | 117° | 131° | 140° |
60 | 6.5 | 12.2 | 15 | 19.3 | 23 | 27 | 33 | 39 | 47 | 55 | 120° | 134° | 142° |
70 | 7.1 | 14.3 | 17.5 | 23 | 27 | 32 | 39 | 45 | 55 | 64 | 123° | 137° | 146° |
80 | 7.5 | 16.3 | 20 | 26 | 31 | 36 | 45 | 52 | 63 | 73 | 127° | 138° | 149° |
90 | 8 | 18.3 | 22 | 29 | 34 | 41 | 50 | 58 | 71 | 82 | 120° | 133° | 140° |
100 | 8.4 | 20 | 25 | 32 | 38 | 46 | 56 | 64 | 79 | 91 | 123° | 136° | 145° |
110 | 8.8 | 22 | 27 | 35 | 42 | 50 | 61 | 71 | 87 | 100 | 125° | 138° | 148° |
120 | 9.3 | 24 | 30 | 39 | 46 | 55 | 67 | 77 | 95 | 109 | 129° | 143° | 150° |
140 | 10.3 | 29 | 35 | 45 | 53 | 64 | 78 | 90 | 111 | 128 | 118° | 127° | 135° |
160 | 11.1 | 33 | 40 | 52 | 61 | 73 | 89 | 103 | 126 | 146 | 121° | 130° | 137° |
180 | 11.5 | 37 | 45 | 58 | 69 | 82 | 100 | 116 | 146 | 164 | 124° | 133° | 139° |
210 | 12.3 | 43 | 52 | 68 | 80 | 96 | 117 | 135 | 166 | 191 | 128° | 139° | 145° |
300 | 14.7 | 61 | 75 | 97 | 114 | 137 | 167 | 193 | 235 | 275 | 110° | 128° | 135° |
450 | 17.9 | 92 | 112 | 145 | 172 | 205 | 2500 | 290 | 355 | 410 | 118° | 132° | 138° |
Ordering information
K | 1/4’’ | – | SS | 1222 |
↓ | ↓ |
| ↓ | ↓ |
Nozzle Type | connector Size |
| Material | Flow code |
General Application:
1) Cleaning and washing process
2) Requiring powerful and concentrated water jets
3) Pressure Washing
4) Foam control in storage tanks and sewage treatment plants

Machine parts

Roll cooling
The production difficulty of the wide-angle fan nozzle is to ensure the wide Angle and uniform spray distribution, both of which are consistent at the same time. However, XinHou spray nozzles can ensure that the angle of our K flat fan nozzles is absolutely accurate, the spray will not disperse, and the water mist at each degree is the same component.
If you have any doubts about the angle selection or the flow impact force of wide-angle fan nozzle K, please do not hesitate to consult us. XinHou spray nozzles will recommend the most suitable wide-angle fan nozzle for your project according to our rich practical experience.