| Measuring Principle | Guided radar | |
| Characteristic / Application | Premium device. Hygiene Rod probe, ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head. | |
| Supply / Communication | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) | |
| Accuracy | Rod probe:+/- 3 mm (0.12 in) | |
| Ambient temperature | -40...+80 °C (-40...+176 °F) | |
| Process temperature | –20...+150 °C ( –4...+302 °F) | |
| Process pressure absolute / max. overpressure limit | Vacuum...16 bar (Vacuum...232 psi) | |
| Main wetted parts | Rod probe: 304, 304L, 316L, PEEK | |
| Process connection | Thread: M24 | |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS | |
| Sensor length | Rod probe: 6 m (20 ft) | |
| Max. measurement distance | Rod: 6 m (20 ft) Min DK>1.6 | |
| Output | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus | |
| Certificates / Approvals | ATEX, FM, CSA, CSA C/US, IECEx, NEPSI Overfill prevention WHG SIL EN10204-3.1 3A, EHEDG CoC ASME-BPE | |
| Options | Sensor remote with 3 m/9 ft or 6 m/18 ft cable Weld-in adpater | |