Membership
Help
Tianjin Enerbyte Electronics Co.,Ltd
Tianjin Enerbyte Electronics Co.,Ltd

Model | ENBY-80V/600Ah | |
Capacity(0.2C5A) | 600Ah | |
Nominal Voltage | 80V | |
Max. Charge Voltage | 90V | |
Discharge Cut-off Voltage | 65V(recommended) | |
Working Voltage Scope | 65V~90V | |
Max. Charge Current | 200A | |
Continuous Discharge current | 300A | |
Max. Discharge current | 500A 10Seconds | |
Weight (Approx.) | 450Kgs(without counterweight) | |
Battery Dimensions | 960*770*400mm | |
Impedance (Max, at 1000Hz) | (Single cell) ≤1mΩ | |
Cycle Life(80DOD%) | >3000 Times | |
Self-discharge Rate | ≤3%(month) | |
Charge Method(CC/CV) | Standard | 100A×6.0hrs |
Quick | 200A×3hrs | |
Operating Temperature | Charge | 0℃~45℃;32oF~113oF |
Discharge | -20℃~60℃;-4oF~149oF | |
Storage | -20℃~45℃;-4oF~113oF | |

Basic data of BMS
| N.0 | Item | Spec | Unit | Remark |
| 1 | Overcharge protect detection voltage | 3.60 | V | Adjustable |
| 2 | Over-discharge protect detection voltage | 2.8 | V | Adjustable |
| 3 | Over-current protect detect value | 600 | A | Adjustable |
| 4 | Discharge current detection delay time | 1 ± 0.5 | S | Adjustable |
| 5 | Charge continue current | 200 | A | Adjustable |
| 6 | Discharge continue current | 300 | A | Adjustable |
| 7 | Overcharge detection delay time | 1 ± 0.5 | Sec | Adjustable |
| 8 | Over-discharge detection delay time | 0.03 ± 0.01 | Sec | Adjustable |
| 9 | Over current/short circuit release | Restart | ||
| 10 | High-temperature protect detect value | 60 ± 3 | ℃ | Adjustable |
| 11 | High-temperature release value | 55 ± 3 | ℃ | Adjustable |
| 12 | Charge Low-temperature protect detect value | 0 | ℃ | Adjustable |
| 13 | Charge Low-temperature release value | 0 | ℃ | Adjustable |
| 14 | Discharge Low-temperature protect detect value | -20 | ℃ | Adjustable |
| 15 | Discharge Low-temperature release value | -15 | ℃ | Adjustable |
| 16 | Balance start_up pressure | 20 | mV | Adjustable |
| 17 | Balance current | 100 ± 5 | mA | Adjustable |
| 18 | Mode of Communication | RS485/CANbus | ||
| 19 | Short circuit protection | Yes | ≤800uS | |
Specification and test curve of battery cells

Specification of battery cells
| 1 | Cell Type | ENBY |
| 2 | Material of Case | Aluminum |
| 3 | Nominal Voltage | 3.2 V |
| 4 | Nominal Capacity | 100Ah |
| 5 | Internal Resistance | <1mW |
| 6 | Discharge Cut-off Voltage | 2.5V |
| 7 | Max Charge Current | 100A |
| 8 | Max Continuous Discharge Current | 1C(100A) |
| 9 | Pulse Discharge Current | 2C 50%SOC (200A within 10seconds) |
| 10 | Max Charge Voltage | 3.65V±0.03V |
| 11 | Charge method | CC/CV (constant current/constant voltage) |
| 12 | Weight | 1.97±0.03kg |
| 13 | Cycle life | 3000 times with 80%DOD |
| 14 | Operating Temperature | Charging Temperature: 0~45℃ Discharging Temperature: -20~60℃ |
| 15 | Storage Temperature | 1 month -30~60℃ 3 month -20~45℃ 1 year -20~45℃ |
| 16 | Relative Humidity | 60±20% |
Precautions
The output voltage of the battery product has exceeded the safe voltage range that can be touched by the human body. Please protect it during installation and use. It is strictly forbidden to directly touch the live part of the battery with any part of the body;
Due to the particularity of lithium batteries, under current technical conditions, there are certain risks during use. Please read this manual carefully before installation and use, and operate strictly in accordance with the instructions in the manual, otherwise it may cause damage to the battery, or even Threat to personal safety.
Matters needing attention:
1)Storage and use environment requirements: The storage environment temperature of the battery system must be within the range of -40℃-60℃. The ambient temperature of the battery must be within the range of -20℃-55℃, and the battery cannot be charged when the ambient temperature is lower than 0℃;
2)Keep away from fire sources during storage of the battery system;
3)The battery system should be protected from rain, water, and other corrosive liquids during transportation, storage, and use;
4)The battery system can only be installed on designated forklifts, and cannot be installed on other vehicles or used on other electrical appliances that exceed the battery specifications;
5)The positive and negative poles need to be prevented from short-circuiting during installation;
6)To charge, you must use the matching special charger, or replace the charger under the guidance of our professionals.
7)When the battery system is not in use for a long time (more than 1 hour), the power switch needs to be turned off. After the power is left unused for more than 1 hour, the battery will automatically enter the dormant state, and the system needs to be turned off and wake up again;
8)After the battery enters the dormant state, there is still a small current flowing through the system. Therefore, when the battery is left for a long time (3 months or more), it is necessary to turn off the power and ensure that the battery power is above 40% SOC. Charge and discharge once every three months Maintenance, that is, charge the battery to 50% after it is discharged. Otherwise, the entire battery pack may be over-discharged, and the failure of the entire battery pack caused by this is not covered by the warranty;
Failure to follow the operating instructions or other reasons for improper use is not covered by the warranty.