1.Introduction:
FPW active power transmitter, FPK reactive power transmitter and FPWK active power/reactive power combined transmitter are instruments that can convert the measured active power and reactive power into DC output. . The converted direct current or voltage is a linear proportional output and reflects the direction of transmission of the measured power in the line. They are suitable for a variety of single and three-phase (balanced or unbalanced) lines with a frequency of 50 Hz, 60 Hz and special frequencies, with appropriate indicating instruments or devices, which can be widely used in power plants and power transmission and transformation systems and other pairs. A place where power measurement is required.
Model specifications:
Accuracy ( 23±3℃) : |
| 0.2% reading / PF ± 0.05% RO | ||
Maximum output load: |
| DC current mode : maximum 10V drop DC voltage mode : maximum 5mA drive | ||
Dielectric strength |
| AC 2KV 1 minute between terminals AC 2.6KV 1 minute / terminals to case | ||
Surge and impulse test |
| ANSI C37.90 / 1989,IEC 255-3 (1989) 4 KV 1.2 x 50 us | ||
Maximum input over |
| Current related input | Voltage related input | |
| 1A/5A | 10A |
| |
| 4xrated/continuous | 2xrated/continuous | 1.5 x rated / continuous | |
| 10xrated/10 seconds | 25xrated/1 second | 2 x rated / 10 seconds | |
| 50xrated/1 second | 50xrated/0.5 second |
| |
| 80xrated/0.5 second |
|
| |
Input burden |
| Current less 0.2 VA; voltage less 0.1 VA | ||
Response time & ripple |
| ≤400 ms for step change 0-99% ripple less 0.5% ro peak to peak | ||
Frequency |
| 50 ± 2 Hz; 60 ± 2 Hz; 400 ± 5 Hz ( Watt only ) | ||
Waveform |
| Watt - 2% 3rd, Var - sinusoidal | ||
Stability |
| Temperature range ( 20 to 26°C ) long term stability / year Maximum 60 ppm / °C less 0.2% draft / year typically..........FPW Maximum 70 ppm / °C less 0.2% draft / year typically..........FPK | ||
Storage condition |
| Temperature range -25 to 70℃, RH 20 to 95% non condensed | ||
Operating condition |
| Temperature range -20 to 65°C, RH 0 to 99% non condensed | ||
Magnetic field effect |
| < 0.01% under 100 ampere turns at 1M center | ||
Power dissipation |
| < 3.5 VA | ||
3.Dimensional Drawings

接线图:

1.Order form:

1. Standard output calibration
bipolar 0 to ± 1mA for 0 to ± D Watts or Vars
4-12-20mA for -D to 0 to +D Watts or Vars
2. External power mode suitably for all output types
Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output
Ordering Information: When signing the order contract, the required model and specifications should be specified in detail. The selected model and specifications should be filled in with the code according to the following format requirements. The special specifications and power correction values are indicated in words.
Example 1:
FPW201-V1-A2-F1-P2-O8 corrected by 1000 W
Three-phase three-wire active power transmitter
Input: 100V 5A 50Hz
Power source: AC 220V
Output: 0-±5V/0-±1000W
Example 2:
FPK201-V1-A2-F1-P2-O1/O8 Corrected by 866var Two outputs
Three-phase three-wire reactive power transmitter
Input: 100V 5A 50Hz
Power source: AC 220V
Output: 0-±1mA/0-±866var