| performance | shallow media filter | Laminated filter | · Hydraulically driven filter |
| Filter form | Deep filtration | Deep filtration | Surface filtration |
| Efficiency | High, with adsorption effect, but Incomplete regeneration affect the filtration effect | High,good trapping effect on soft and fiber impurities | Medium,poor rapping effect on soft and fiber impurities |
| Backwash effect | Medium | good | Medium |
| · Backwash interval period | long | Medium | short |
| Total recoil water | high | low | Medium |
| Area | large | small | small |
| Model | inlet &outlet (DN) | Backwash pipe (DN) | · Recommended water treatment capacity (m3/h) | maximum pressure(MPa) | Water treatment capacity at different filtration speeds(m3/h) | ||||
| 25m/h | 35m/h | 45m/h | 50m/h | 60m/h | |||||
| JMF-400×2 | 65 | 65 | 20 | 1.0 | 6.3 | 8.8 | 11.3 | 12.6 | 15.1 |
| JMF-400×3 | 80 | 65 | 30 | 1.0 | 9.5 | 13.2 | 16.9 | 18.9 | 22.6 |
| JMF-500×2 | 80 | 65 | 36 | 1.0 | 9.8 | 13.7 | 17.6 | 19.6 | 23.5 |
| JMF-500×3 | 80 | 65 | 54 | 1.0 | 14.7 | 20.5 | 26.4 | 29.4 | 35.2 |
| JMF-600×2 | 80 | 65 | 50 | 1.0 | 14.1 | 19.9 | 24.4 | 28.3 | 33.9 |
| JMF-600×3 | 80 | 65 | 75 | 1.0 | 21.1 | 29.8 | 36.6 | 42.4 | 50.8 |
| JMF-750×2 | 100 | 65 | 70 | 0.8 | 22.1 | 30.9 | 39.7 | 44.2 | 53 |
| JMF-750×3 | 100 | 65 | 105 | 0.8 | 33.1 | 46.3 | 59.5 | 66.3 | 79.5 |
| JMF-900×2 | 100 | 65 | 100 | 0.8 | 31.8 | 44.5 | 57.2 | 63.6 | 76.3 |
| JMF-900×3 | 100 | 65 | 150 | 0.8 | 47.7 | 66.7 | 85.8 | 95.4 | 114.4 |
| JMF-1000×2 | 150 | 80 | 130 | 0.8 | 39.3 | 54.9 | 70.65 | 78.5 | 94.2 |
| JMF-1000×3 | 150 | 80 | 195 | 0.8 | 58.9 | 82.3 | 105.9 | 117.7 | 141.3 |
| JMF-1200×2 | 150 | 80 | 180 | 0.6 | 56.5 | 79.2 | 101.7 | 113.1 | 135.7 |
| JMF-1200×3 | 150 | 80 | 270 | 0.6 | 84.7 | 118.8 | 152.5 | 169.6 | 203.5 |
| JMF-1200×4 | 200 | 80 | 360 | 0.6 | 112.9 | 158.4 | 203.3 | 226.1 | 271.3 |
| JMF-1200×5 | 200 | 80 | 450 | 0.6 | 141.1 | 198.0 | 254.1 | 282.6 | 339.1 |
| JMF-1200×6 | 200 | 80 | 540 | 0.6 | 169.3 | 237.6 | 304.9 | 339.1 | 406.9 |
| Item | problems | cause | solution |
| 1 | Outflow is too small | a. low water pressure b. small diameter c. Less filter unit design d. Not washing in time | a. increase water pressure b. Increase the pipe diameter c. Add filtration unit d. Reduce cycle time or backwash startup differential pressure |
| 2 | Poor effluent quality | a. less sandstone b. backwash is not thorough | a. Refilling sandstone b. Increase backwash time |
| 3 | Backwash of one or more units not start | broken Circuit | Check the corresponding lines |
| 4 | Backwash valve not closed tightly | a. Valve switching failure or foreign matter stuck on the sealing surface b. Back pressure of outlet pipe is less than <0.15Mpa | a. Open the backwash valve, clean and repair b. Increase the inlet pressure or reduce the outlet valve, and increase the back pressure> 0.15Mpa |
| 5 | Backwashing too frequent | a. Raw water impurities are too high b. The differential pressure start value is too small or the time start interval is too small | a. Increase raw water pretreatment b. Reset the differential pressure or time start parameters |
| 6 | Incomplete backwash | a. Backwash pressure <0.15Mpa b. Excessive drain pipe or valve resistance | a. Increase the inlet water pressure or reduce the outlet valve, increase the back pressure> 0.15Mpa b. Dredge the drain pipe or increase the pipe diameter and valves |
| 7 | No backwash water pressure signal | a. Pressure water filter is blocked b. The signal tube is blocked c. Controller setting problem or electrical failure | a. Cleaning the pressure water filter b. Dredge and clean the signal tube c. Check controller settings and troubleshoot |