Welcome Customer !

Membership

XwbooElectronic ComponentsPiezoelectric Crystal, Frequency ElementTransducerGPW/GPK WATT & VAR TRANSDUCER
  • $item.Title
  • $item.Title

GPW/GPK WATT & VAR TRANSDUCER

Haiyan Jinhan Electronics Technology Co., Ltd.

Model
Nature of the Manufacturer
Other
Product Category
Transducer
Place of Origin
,
Applied Standards & Rules:Measuring and conversion:IEC 688 / 1992 - 04Dielectrical strength:IEC 688 2KVac/1 min.Surge and Impulse test:ANSI C37.90 / 1989,IEC 255-3 (1989) 4KV1.2x50us

GPW/GPK active power / reactive power transducer

GPWK active power / reactive power combined transducer

GPWA/GPKA active power current / reactive power current combination transducer

1.Introduction:

Time-division-multiplication (TDM) principle of computing the AC power inputs to a corresponding DC output value. The measurements of active power of single or three phase balanced or unbalanced systems, are precisely converted to a highly accurate linear DC voltage or current output.

Applied Standards & Rules:

Measuring and conversion:IEC 688 / 1992 - 04

Dielectrical strength:IEC 688 2KVac/1 min.

Surge and Impulse test:ANSI C37.90 / 1989,IEC 255-3 (1989) 4KV1.2x50us

2.Models and specifications:

GPW101: 1 phase 2 wires watt

GPW201: 3 phase 3 wires watt

GPWT201: 3 phase 3 wires watt(Dual output)

GPW301: 3 phase 4 wires watt

GPWT301: 3 phase 4 wires watt(Dual output)

GPK201: 3 phase 3 wires Var

GPKT201: 3 phase 3 wires Var(Dual output)

GPK301: 3 phase 4 wires Var

GPKT301: 3 phase 4 wires Var(Dual output)

GPWK201: 1 phase 2 wires watt&Var

GPWKA201:3 phase 3 wires watt&Var&1Current

GPWK301: 3 phase 4 wires watt&Var


3.Specification

Reference Standard:

GB/T 13850-1998(IEC688-1992)

Accuracy:

0.5%

Long term stability:

≤±0.5%/year,No accumulation error

Temperature influence:

<100ppm/℃

Response Time:

<400ms

Output Ripple:

<1.0% (peak-peak value)

Input burden:

Current less 0.2VA;voltage less 0.1VA

Frequency:

Nominal frequency ±10%

Maximum output load:

Current output Max10V pressure drop

Voltage output rated 2mA MAX 5mA output

Auxiliary power:

WATT unit: <3.5VA,VAR unit <3.5VA,Current unit <3VA.

Auxiliary load effect:

<0. 2 %

Allow excessive input:

Current 2 rate continuous 20 rate

1 secs voltage max 2 rate continuous

Dielectric strength:

Input/output/power/betwem the crust 2KV,AC 1 min IEC866

Impact test:

ANSI C37.90a/1973,IEC 255-4,(5kV 1.2/50us Pulsed Voltage)

Calibration amplitude:

Full scale least<±3%,zero least<±1%

Magnetic field effect:

0.4KA/m magnetic field strength change<0.05%

Operating condition:

Temperature -10~55℃relative humidity

≤95% RH non condensing

Storage condition:

Temperature-40~70℃ relative humidity

≤95% RH non condensing



4.Terminal Connection:


5. Dimensional Drawings:


1.Order form:


2.Input & Output parameters

Vn :

Voltage input

Vn

rating range

V1

100
80-120VV

V2

220V

180-300V

V3

400V

320-450V

Vy

Specified

On : Output

An :

Current input

An

rating range

A1

1A

0-1.2A

A2

5A

0-6A

A3

10A

0-12A

Ay

Specified

O1

0-±1mA

O2

0-±20mA

O3

4-20mA

Fn :

Frequency input

Fn

rating range

F1

50Hz

45-55Hz

F2

60Hz

55-65Hz

F3

400Hz

Fy

Specified

O4

0-±5mA

O5

0-±10mA

O6

4-12-20mA

Pn :

Auxiliary power

Pn

rating range

P1

AC110 V

120 V ± 15%

P2

AC220 V

240 V ± 15%

Ps

Internal Power

Py

Specified

O7

0-±1V

O8

0-±5V

O9

0-±10V

PDn

rating range

PD1

DC110V

120 V ± 15%

PD2

DC220V

240V± 15%

PD3

D, , , C24 V

24 V ± 20%

PDy

Specified

O10

2-10V

O11

1-5V

O12

1-3-5V


Note:

1. Standard output calibration

bipolar 0 to ± 1mA for 0 to ± D Watts or Vars

4-12-20mA for -D to 0 to +D Watts or Vars

2. External power mode suitably for all output types

Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output


Example : 1:GPW201-V1-A2-F1-P2-O8 Correction by 1000 W

3 phase 3 wires active power transducer

Input:100V 5A 50Hz

Power:AC 220V

Output:0-±5V/0-±1000W

Example : 2:GPKT201-V1-A2-F1-P2-O1/O8 Calibrating by 866var,Two-way output

3 phase 3 wires active power transducer

Input:100V 5A 50Hz

Power:AC 220V

Output:0-±1mA/0-±866var 0-±5V/0-±866var

Haiyan Jinhan Electronics Technology Co., Ltd was founded on November 18, 2004 which located in Haiyan Science and Technology Park, NO 211, Yanbei Road, Zhejiang China.Our goal is to design and manufacture multiple series of products for power systems. With the ISO9001 / ISO9002 approvals, we have always sustained the principle of producing the best quality, best service and best technical skills.For over 10 years, JINHANCN has contributed and always strived to develop the most durable and stable products for the usage of power systems. We have earned excellent customer feedback and marketing reputation from all over the world.Our products have been applied to both measuring instruments and power distribution systems for utilities and related industries. And we also have developed various series of products to meet the demands of various marketing such as FP/GP/EP/S3/N3 Series High-reliability Power Transmitter, Transmission Screen, Malfunctional Electric Energy Meter, Temperature Controller etc.We truly believe that to give our customers the best service is our main purpose and long-term responsibility.With spirited teamwork, our business has expanded to global markets successfully. All JINHANCN products are originally designed and manufactured (ODM).We have been researching and developing new high-tech products continually in order to meet increasing demand for electricity. To improve business administration and quality assurance, we run CWQC (company wide quality control) with strict step by step quality compliance to our production procedure in compliance with ISO9001.