Membership
Help
Shenzhen ZLPOWER Electronics Co., Ltd.
Shenzhen ZLPOWER Electronics Co., Ltd.
Features:
GS Series AC/Solar charging Off grid Hybrid lnverter.
LED/LCD display,Enhanced functions setting via LCD,Man-machine intelligent design.
Built-in 40A/60A optional MPPT solar charger controller.
LCD shows the solar capacity.
5 stages adjustable AC charging current. AC charging also can be closed.
AC/DC priority modes can be closed.
Generator restart signal(Dry contact).
3 times peak power.Strong loading capacity.
Overload,output short-circuit protection.
Specifications:
| Model | GS1000 | GS2000 | GS3000 | GS4000 | GS5000 | GS6000 | GS8000 | GS10KW | GS12KW | |
| Power Rating | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10KW | 12KW | |
AC Input | Input Voltage Waveform | Sinusoidal(utility or generator) | ||||||||
Nominal input Voltage | 120/230VAC | 230VAC | ||||||||
Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4%(Wide) for 120Vac 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230Vac | 184Vac±4%(Normal) or 135Vac±4%(Wide) for230Vac | ||||||||
Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120Vac 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230Vac | 194Vac±4%(Normal)or 145Vac±4%(Wide) for230Vac | ||||||||
High Line Disconnect | 136Vac±4%(Normal) or 145Vac±4%(Wide) for 120Vac 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230Vac | 263Vac±4%(Normal) or 263Vac±4%(Wide) for230Vac | ||||||||
Max AC input Voltage | 120Vac for Max150Vac, 230Vac for Max270Vac | 230Vacfor Max270Vac | ||||||||
| Frequency | 50Hz:41-54Hz,60Hz:51-64Hz | |||||||||
| AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5 stages adjustable charging current) | ||||||||
Over Charge Protection | Bat.V>15.5VDCfor 12V battery ; Bat.V>31.0VDC for 24V battery, Bat.VN62.0VDC for 48V battery ; beeps 0.5s every 1s & fault after 60s | |||||||||
| Solar Charger | Rated Charge Current | 40A | 60A | 60A | 60A/120A | 60A/120A | 60A/120A | 60A/120A | 60A/120A | 60A/120A |
PV Input Voltage range | 12VDC. 25VDC-75VDC for 24VDC. 55-145VDC for 48V | |||||||||
Max.PV open circuit array voltage | 12V for40VDC, 24V for 75VDC, 48V for 145VDC | |||||||||
| Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV>Bat.V=3V | |||||||||
PV Low Voltage Disconnect | PVWBat.V | |||||||||
| Efficiency | >97% | |||||||||
| Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(According to the inverter model), 5 stages adjustable charging current | ||||||||
Over charge Protection | Bat.V>15.5VDC/31VDC/62VDC,beeps 0.5s every 1s & fault after 60s | |||||||||
| Efficiency | Efficiency (Battery Mode ) | >87% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
| Battery Voltage | Nominal DC Input Voltage | 12/24/48VDC | 24/48VDC | 48VDC | ||||||
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC, 21VDC±0.6VDC for 24VDC, 42VDC±1.2VDC for48VDC | |||||||||
Low DC input shut-down | 10VDC±0.3VDC for 12VDC, 20VDC±0.6VDC for 24VDC, 40VDC±1.2VDC for48VDC | |||||||||
High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC, 32VDC±0.6VDC for 24VDC, 64VDC±1.2VDC for48VDC | |||||||||
| Transfer Time | AC to DC DC to AC | 20ms(max) 15ms(max) | ||||||||
| System Parameter | Over-Load Protection | 110% | ||||||||
| Output Short Circuit Protection | Current limit(Fault after 10s) | |||||||||
Surge Rating (10s) | 1:3(VA) | |||||||||
| Power Saver | Load<25W(Enabled on "P/S auto"Setting of Remote control) | |||||||||
| Protections | Low battery.over charging,over load,over temp | |||||||||
| Indicators | LED+LCD Display | |||||||||
| General Specification | Operating Temperature Range | 0°C to 40°C | ||||||||
| Storage Temperature | -15°C 〜60°C | |||||||||
| Operation humidity | 5% to 95%(non-condensing) | |||||||||
| Audible Noise | 60dB max | |||||||||
| cooling | Forced air,variable speed fan | |||||||||
| Dimension(L*W*H) | 480*336*190mm | 530*400*190mm | 627*416*204mm | |||||||
| Net Weight(kg) | 19.5kg | 23.5kg | 28.0kg | 30.0kg | 35.5kg | 39.0kg | 52.5kg | 58.5kg | 66.5kg | |