Order Data
Model No. | Series | Specification | Order No. |
H32-01 | CTH-300 | H32-01,256KB+64KB PM,1MB DM,32KB DM when power down,1*PPI/Free port,1*EtherNET port.1*USB port,1*CAN port,1*EtherCAT port.Support uni axial motion control.Support interpolation (line and arc),Support electronic CAM and electronic gear.The maximum number of racks is 1. | CTH3 H32-001S2 |
Performance Parameters
| Series | Motion Control Thin CPU |
| Model no. | H32-01 |
| Order no. | CTH3 H32-001S2 |
| Bit instruction processing time | 0.086us/step |
| Floating-point instruction processing time | 1.4us/step |
| User program memory | 256KB+64K |
| Data memory | 1MB |
| Power down permanently maintains data memory | 32KB |
| Power down keep mode | FlashROM |
| System indicator | 7 |
| RUN/STOP dialing code | Yes,2 states |
| Analog potentiometer | No |
| Real-time clock | Built in |
| Battery card interface | No |
| Data area and retention features | |||||
| Data area type | Size | Addressing range | Addressing property | Access property | Hold property |
| Digital volume (I) | 256bytes | IB0-IB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported |
| Digital volume(Q) | 256bytes | QB0-QB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported |
| Analog volume (AI) | 1024bytes | AIW0-AIW1022 | Only writes | Immediate access/direct access/indirect access | Power down hold data are not supported |
| Analog volume (AQ) | 1024bytes | AIW0-AIW1022 | Only writes | Immediate access/direct access/indirect access | Power down hold data are not supported |
| Variable memory(V) | 65536bytes | VB0-VB65535 | Read/write | Direct access/indirect access | VB0-VB10239 Power down hold data |
| Special memory area(SM) | 2048bytes | SMB0-SMB2047 | SMB0-SMB29 Read/writ/SMB30-SMB2047 Read/writ | Direct access/indirect access | Power down hold data are not supported |
| Bit memory(M) | 32bytes | MB0-MB31 | Read/write | Direct access/indirect access | Power down hold data |
| Local Variable(L) | 128bytes | LB0-LB127 | Read/write | Direct access | Startup to stop the same call position subroutine can be keep,power down hold data are not supported |
| Accumulator register(AC) | 4 | AC0-AC3 | Read/write | Direct access | Power down hold data are not supported |
| Step register (S) | 32bytes | SB0-SB31 | Read/write | Direct access/indirect access | Power down hold data are not supported |
| Timers (T) | 1ms*36 10ms*752 100ms*1260 | T0-T2047 | — | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold |
| Counter(C) | 2048 | C0-C2047 | — | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold |
| Data Block(DB) | 512KB | — | Read/write | Direct access/indirect access | 16KB Power down hold data |
| Physical Features | |
| Dimension(W×H×D) | 34 x 115 x 101.6mm |
| Power dissipation | 19.2W |
| Power supply features | |
| Rated input voltage | 24V DC |
| Input voltage | 20.4V -28.8VDC |
| Input current | 0.8A |
| Polarity reverse connection protection | Yes |
| Bus power supply voltage | +5V DC |
| Bus power supply current | 1.6A |
| LED indicator characteristics | ||
| 24V power indicator | Green | ON = 24VDC power supply normal, OFF = no 24VDC power supply |
| SF indicator | Red | ON = system failure, OFF = no error |
| BF indicator | Red | ON = bus fault, OFF = no error |
| FRCE indicator | Yellow | ON = coercion of an item, OFF = NO coercion of an item (can also be controlled through the FLC command) |
| RMC indicator | Green | ON: CPU has successfully communicated with the remote server (dialing switch 3 is ON and Ethernet communication port parameters have been correctly configured) |
| Off | OFF:CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch) | |
| RUN indicator | Green | ON = system running, OFF = system stop |
| STOP indicator | Orange | ON = system stop, OFF = system running |
| EtherNET indicator | Green | ON = connected, OFF = disconnected |
| Yellow | ON = 100Mbps,OFF = 10Mbps | |
| EtherCAT indicator | Green | ON = connected, OFF = disconnected |
| Yellow | ON = 100Mbps,OFF = 10Mbps | |
| Expand I/O capabilities | ||
| IO expand | Maximum number of racks of 1CPU | 1 |
| Maximum number of modules supported per rack | Support up to 8 modules except power, CPU, relay module | |
Integrated communication function | |||||||
| Port number | Ethernet port:1 | ||||||
| Serial port:1(RS485) | |||||||
| USB:1 | |||||||
| EtherNET communication port | Communication port | 1*EtherNET port | |||||
| Baud rate | 10/100Mbps adaptive | ||||||
| Protocol types | Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU | ||||||
| Maximum length of each cable | 100m directly connected | ||||||
| The maximum number of connections per site | UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP | ||||||
| Quantity of user data | Up to 200 bytes for UDP_PPI transfer, Up to 240 bytes for ModBus_TCP transmission, A maximum of 512 bytes are used for Socket transmission | ||||||
| DHCP function | Support | ||||||
| Remote monitoring/programming | Support | ||||||
| Isolation | Communication port isolation | ||||||
| Serial port(RS485) | communication port | 1 PPI/ free port switchable port, with 24VDC output | |||||
| Data transfer rate | PPI/MPI:9.6K/19.2K/187.5K | ||||||
| Free port::1.2K-115.2K | |||||||
| Maximum number of stations | 32 for each segment and 126 for each network | ||||||
| Maximum number of master stations | 32 | ||||||
| Point-to-point (PPI master mode) | Yes (NETR/NETW), with a maximum of 8 connections, each connection communicating a maximum of 200 bytes | ||||||
| MPI connections | (1PG/1OP)8,with 2 reserved | ||||||
| Maximum cable length per segment | Using isolation repeater: 1000m at 187.5kbps and 1200m at 38.4kbps | ||||||
| No isolation repeater used:50m | |||||||
| Isolation | Communication port isolation | ||||||
| CPU and USB interface specification | Interface form | USB A type female port | |||||
| Programmable card media | USB flash drive | ||||||
| Download /upload feature | Support | ||||||
| Formulation function | Support | ||||||
| Data record archiving function | Support | ||||||
| CANopen function | ||||||||
| CANopen | Communication module | CANopen module | ||||||
| Maximum number of slave stations | 1 master station can be followed by a maximum of 32 slave stations | |||||||
| Protocol type | CANopen DS301standard protocol | |||||||
| Support functions | Supports automatic starting of CANopen Manager | |||||||
| Supports optional slave polling | ||||||||
| Support to start slave stations | ||||||||
| Support NMT | ||||||||
| Support synchronous production | ||||||||
| Support synchronous consumption | ||||||||
| Support heartbeat generation | ||||||||
| Support activation time creation | ||||||||
| Transmission rate(kbit/s) | 1000 | 800 | 500 | 250 | 125 | 50 | 25 | |
| Maximum length(m) | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 | |
| Isolation | Communication port isolation | |||||||
| Thin PLC master control unit requirements table 4- user program elements | ||
| Thin | ||
| Basic instruction set | CTH300-H Basic instruction set | |
| Programming software | Magicworks PLC V2.00 and above | |
| Programming port | 1*RS485 port 1*Ethernet port 1*USB port | |
| On-line programming | Support | |
| Programming language | Statement table STL Ladder diagram LAD | |
| FB/FC/DB function | Support | |
| Accumulators | 4 | |
| Timer | 2048 | |
| Counter | 2048 | |
Power interface definition
4pin terminals spaced at 3.81mm apart | Symbol | Signal definition |
| L+ | +24V power |
M | +24V power ground | |
| Ground | |
-- | -- |
USB interface definition
USB port | No. | Signal | Signal definition |
![]() | 1 | V_BUS | +5V power |
2 | Data- | Data- | |
3 | Data+ | Data+ | |
4 | GND | Ground |
EtherNET interface definition
RJ45 port | No. | Signal | Signal definition |
| 1 | TX+ | Positive end of data transmission |
2 | TX- | Negative end of data transmission | |
3 | RX+ | Positive end of data transmission | |
4 | TERM | -- | |
5 | TERM | -- | |
6 | RX- | Negative end of data transmission | |
7 | TERM | -- | |
8 | TERM | -- | |
Shell | PE | Shell ground | |
Green indicator | As an indication of EtherNET connection status | ||
Yellow indicator | As an indication of EtherNET connection status | ||
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart | ||
6pin terminals | Signal | Signal definition |
| A0 | PORT0 RS485 signal A |
B0 | PORT0 RS485 signal B | |
SG | PORT0 RS485 signal ground | |
A0 | PORT0 RS485 signal A | |
B0 | PORT0 RS485 signal B | |
SG | PORT0 RS485 signal ground | |
Dial switch definition
Dial switch | Symbol | Dial direction | Signal definition |
| RUN | Up | System operation |
STOP | Down | System halt | |
Swivel 5 times in 3 seconds | Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
DIP dial | No. | Symbol | Signal definition | Note |
| 1 | Term-PORT0 | Terminal resistance switch 1(PORT0) | ON:with terminal resistance OFF:without terminal resistance |
2 | Term-PORT1 (H35-00) | Terminal resistance switch 2(PORT1) | ON:with terminal resistance OFF:without terminal resistance | |
NC (H36-00/H36-01) | -- | -- | ||
3 | RMC-SW | Remote control switch | ON:Remote control allow OFF:Remote control forbid |